Troubleshooting / Tips - T.I.P. SPF 180 Instrucciones Para El Manejo

Juego de filtros para piscinas
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

age. Store the pump at a dry and frost-proof location. If the pump is operated again after a longer
break, please ensure all sealing and und O-Rings are in good condition. Replace any defect or dam-
aged sealing's.
Check, if the motor shaft is moving freely before each new operation.
Check and clean the tube with filter basket (fig. 8, No. 5) in the sand filter tank (fig. 8) in regular inter-
vals.
1. Remove the lid with 4 position valve (fig. 8, No. 1) and take out the tube with filter basket
(fig. 8, No. 5).
2. Clean the filter basket with clear water.
3. Do the assembly in reverse order. Check the sealing of the lid (fig. 8, No. 3). Replace damaged
sealing's immediately.
4. Insert the tube with the filter basked (fig. 8, No. 5).
5. Fill the sand filter tank again.
6. Place the o-ring correctly.
7. Pull the lid by hand.
8. Switch on the pump again.
A regular check of the mechanical and electric parts is recommended:
1. The accurate and right connection of adapters, hose and pipes and secured tightness of all screws.
2. The correct condition of all electric connections and power cords.
3. The vibration of the pump. In case of an excess high vibration, stop the pump immediately and con-
tact your service partner or the manufacturer.

10. Troubleshooting / tips

In the case of malfunction, you should first of all check whether it was caused by an operating error or
some other reason which cannot be attributed to a defect of the device - for instance a power failure.
The list below shows some possible malfunctions of the device, possible causes and tips on their elim-
ination. All the measures referred to may only be carried out with the pump being separated from the
electrical mains. If you yourself feel unable to eliminate any of these malfunctions, please contact the
customer service department or your point of sales. Any repair beyond the scope specified below must
only be performed by qualified staff. Please bear in mind that all warranty claims will become void in
the case of damage caused by inappropriate repair attempts, and that we decline any liability for any
ensuing damage.
M
1. The pump is not discharg-
ALFUNCTION
ing any liquid, the motor is not
running.
2. The motor is running, but
the pump is not discharging
any liquid.
P
C
1. No current.
OSSIBLE
AUSE
2. Thermal motor protection feature
has triggered.
3. The capacitor is defective.
1. The pump housing is not filled
with liquid.
2. Air penetrates into the pump body.
3. Check valve (non-return valve), if
present, is blocked or defective.
1. Please use a device complying with GS
(German technical supervisory authority) to
check for the presence of voltage (safety in-
for mation to be observed!). Please verify the
correct position of the plug.
2. Separate the pump from the electrical
mains, allow the system to cool down, elimi-
nate cause.
3. Please contact the customer service de-
partment.
1. Ensure the water level in the pool is
above the suction point of the pump. Make
sure the strainer is free of dirt
2. Check to make sure that:
a. the connection points of the intake line
are tight;
b. No siphons (i.e. permanently liquid-filled
loops), kinks, counter-slopes or narrow
spots are present along the intake lines.
3. Eliminate blocking of the check valve
(non-return valve) or replace, if damaged.
Clean the insert of the pump and check any
blockage of the impeller
9
E
LIMINATION
24

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Spf 250 fSpf 370 f

Tabla de contenido