6.1.

Return path filter

The return path signal can be filtered at any point of the line of the amplifier. Place the
connectors at the indicated positions.
6.2.

Return path amplification

Like the previous case, it is possible to select if amplification or passive pass is required for
the treatment of the return path signal. In passive mode, it has a gain of -2.5dB and in active
mode of +25dB.
Igual que en el caso anterior, es posible seleccionar si queremos amplificación o un
comportamiento pasivo en el tratamiento del canal de retorno. En pasivo, tienen una ganancia
de -2.5dB y en activo de 25dB.
6.3.

Equalization and attenuation of the return path

Like the forward path it is possible to adjust attenuation and equalization to reach with the
right level to the previous node.

7. Test points

The amplifier is equipped with the following test points:
bi-directional at the input
directional at the output
directional in the return path
The signal level at the test points is 20 dB lower than the useful signal.