►►3.5. INSTALLING THE DRAIN
VALVE
(Pic. 6)
At the base of the cooler, to drain water
from the tank, the cooler is equipped with a
drain valve.
At the time of purchase, the drain valve
comes in the kit supplied.
To install the valve you must:
►3.5.1. Remove the nut installed at the
base of the valve.
►3.5.2. Insert the valve into its seat (locat-
ed at the base of the cooler).
►3.5.3. Screw the nut back onto the valve.
►►3.6. CONNECTING TO THE WATER
MAINS
(Pic. 7)
IMPORTANT: ONLY FEED THE COOLER
WITH CLEAN WATER.
IMPORTANT: THE COOLER CAN WITH-
STAND A MAXIMUM WATER INLET
PRESSURE OF 3 BAR. THE PIPES AND
FITTINGS USED FOR THE WATER SUP-
PLY MUST BE OF ADEQUATE SECTION
AND STRUCTURE (IF THE PRESSURE
OF THE WATER MAINS IS HIGH, WE
RECOMMEND USING A PRESSURE RE-
DUCER AND A METAL MESH PIPE).
►3.6.1. Connect the cooler to the water
mains by using the threaded fitting and
the solenoid valve.
►3.6.2. Connect the solenoid valve to the
electrical panel, by feeding the electrical
cables through the hole near the electri-
cal panel on the bottom of the cooler.
►3.6.3. Make sure that there are no water
leaks in the circuit before commissioning.
►►3.7. BASIC CONFIGURATION
(Pic. 8)
IMPORTANT: USE A CABLE WITH SPE-
CIFIC CHARACTERISTICS FOR THE
SYSTEM TO WORK CORRECTLY (SEE
THE TECHNICAL DATA TABLE).
IMPORTANT: THE BASIC CONFIGURA-
TION OF THE COOLER MUST BE CAR-
RIED OUT FROM THE DISPLAY AFTER
HAVING ASSIGNED A UNIQUE AD-
DRESS TO EACH MACHINE DURING IN-
STALLATION.
►3.7.1. Log in and access the MAIN menu.
►3.7.2. Use the CONFIG menu to map
the system, showing which coolers are
present in the 31 possible.
►3.7.3. From the MAIN menu select all
the coolers in the system (one cooler at
a time), by accessing the relevant menu,
and set:
1- INDIVIDUAL OR AREA OPERATING
MODE:
-INDIVIDUAL OPERATION:
Autonomous operation that requires the
presence of the probe.
-ARE OPERATION:
Overall logic (assign one of the 4 possible
relevant AREAS) and define a "LEADER"
machine within each AREA, which
must be equipped with a temperature /
humidity probe (based on the model).
The "SLAVE" coolers do not need a
probe to operate.
2 - MODE (COOLING / VENTILATION /
INTAKE / CLEANING):
Select the button according to mode you
want to set.
3 - HOURLY SETTING:
-Select AUTO in the TIMER box to set
the hourly setting (the TIMER button is
activated).
-Select MAN in the TIMER box to
manually set the cooler on and off.
4 - OPERATING MODES WITH
TEMPERATURE OR HUMIDITY LIMITS
(BASED ON THE MODEL):
Use the specific drop-down menu, based
on the model, to choose the temperature
or humidity as a reference parameter.
Selecting LOCAL defines the "LEADER"
cooler of an area; similarly, selecting
AREA defines a "SLAVE" cooler. Moving
the cursor to LIMIT allows you to set the
reference value for the temperature or
humidity (based on the model).
en
it
de
es
fr
nl
pt
da
fi
no
sv
pl
ru
cs
hu
sl
tr
hr
lt
lv
et
ro
sk
bg
uk
bs
el
zh

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Bcm 191alBcm 191auBcm 311abBcm 311auBcm 511abBcm 511au

Tabla de contenido