ADVANCED SYSTEM SETUP
The following four features are done in a
flow-through setup. The system will walk you
through each feature. To access only one
feature, follow these steps then press SET
until you come to the feature you would like
to adjust.
1.
Slide the MODE switch to the off
position.
2. While holding the RESET button press
SET, "offset" will appear on the display.
Note: Do not hold the reset button for more
than five seconds.
3. Release both buttons.
Note: The system will automatically exit if no
button is pressed within 12 seconds.
18
TEMPERATURE OFFSET
Offset the temperature display to read +/- 9°
F (+/- 4.5° C). This thermostat has a highly
accurate temperature sensor; if you desire
to match the display with other devices this
offset feature can be used.
Note: Using this feature does not change the actual
temperature.
1.
Press p or q to change the offset
amount.
2. Press SET to advance to the next step.
To exit, press SET four times.
EARLY START
Your thermostat comes preprogrammed
with early start functionality turned off. This
function allows the heating or cooling system
to turn on before the programmed start time
so that the room temperature matches the
set temperature at the start time.
1.
Press p or q to toggle between OFF
and ON.
2. Press SET to advance to the next step.
To exit, press SET three times.
SYSTEM TYPE
Your thermostat is set at the factory to
operate a standard fossil fuel furnace
heating system.
1.
Press p or q to toggle between the
heat systems being used.
• If using a Heat Pump select HP.
• If using a Furnace select F.
2. Press SET to advance to the next step.
To exit, press SET two times.
19