MINIMUM CYCLE PERIOD
Changing the minimum cycle period to
six minutes or greater enables smart
logic. When this feature is enabled, your
thermostat will learn, over time, the best
cycle times for your system and home
conditions. Using smart logic can optimize
energy use and comfort level, and allow for
setting the thermostat to turn on the system
more or less frequently.
1.
Press p or q to select the desired
cycle period.
2. Press SET to accept the cycle period
and exit.
20
If Heat Pump (HP) has been selected,
it will toggle between 60, 30, 20, 15,
12 and 0.
If Furnace (F) has been selected, it will
toggle between 60, 30, 20, 15, 12, 10, 8,
6 and 0.
Common Cycle Period Settings
System Type
1-Stage gas furnace heat with electric fan
1-Stage gas furnace heat with gas fan
1-Stage oil furnace
F
Steam and gravity
Hot water system
High efficiency furnace
Electric furnace
1-Stage heat pump
HP
Compressor
MINIMUM CYCLE PERIOD
Cycle Period
(Minutes)
12
12
12
60
20
20
6
20
20