Warning
• Install the equipment by carefully following the instructions given by the manufacturer and in compliance with the standards in force.
• All the equipment must only be used for the purpose it was designed for. Comelit Group S.p.A. declines any responsibility for improper use of the apparatus, for any alterations
made by others for any reason or for the use of non-original accessories or materials.
• All the products comply with the requirements of the 2014/30/EU and 2014/35/EU directives. This is proved by the CE mark on the products themselves.
• Do not route the riser wires in proximity to power supply cables (230/400V).
• Installation, mounting and assistance procedures for electrical devices must only be performed by specialised electricians.
• Disconnect the power supply before carrying out any maintenance work.
Operation and programming
Art. 1409 can be used to manage analogue CCTV cameras (up to 3).
Art.  1409 can be used in systems with Art. 1210 or 1209, and in
systems with Art. 4888C in the SB2 section (running from mixer power
supply unit towards the door entry monitors/door-entry phones).
√ With monitor on
„ Press the programmed button to cycle through all connected
cameras, in accordance with the diagram below. Sequential
switching can also be activated using a clean contact (C-NO)
connected to the INA – GND input (see diagram: SB2V/023ASMC).
MODE WITH AUDIO PORTER OR SWITCHBOARD
External unit
1st camera
GENERIC OR CODED ACTUATOR MODE
DEFAULT CONFIGURATION
MODE
DIP 1 DIP 2 DIP 3
Video porter
Generic actuator
ON
ON
3 cameras
PROGRAMMING THE NUMBER OF CAMERAS CONNECTED
„ Set the number of cameras connected using dip switches 7 and
8, as shown in the table below:
DIP 7
4
1.
2.
3.
4.
5.
6.
2nd camera
3rd camera
DIP 4
DIP 5
DIP 6 DIP 7 DIP 8
OFF
OFF
OFF
OFF
ON
DIP 8
0
0
1
0
0
1
1
1
1. Terminal block M2 for system connection:
Camera module external control contact
INA
Common contact
GND
Coax input camera 1
V1 S1
Coax input camera 2
V2 S2
Coax input camera 3
V3 S3
2.
Controls frequency of video signal modulation
TRIMMER TM2
(factory set to optimum setting: do not adjust)
3.
Controls amplitude of modulated video signal
TRIMMER TM1
(factory set to optimum setting: do not adjust)
4. Programming microswitches
5. Indicator LED DL1
off: no video coming from cameras 1, 2 or 3
on: the video transmitted on the monitor is coming from camera
1, 2 or 3
6. Terminal block M1 for system connection:
L OUT L OUT Bus line output
L IN L IN Bus line input
~- ~+12 Vac 20 Vdc power supply input
1. GENERIC ACTUATOR MODE
Before programming the module, see "5. Art. 1409
compatibility table"
In this mode and with the door entry phone monitor switched on, it
is possible to cycle through all the connected cameras by repeatedly
pressing the button programmed as "generic actuator".
„ Microswitch "S1" must be set as
illustrated below
2. CODED ACTUATOR MODE
Before programming the module, see "5. Art. 1409
compatibility table"
In this mode and with the door entry phone monitor switched on, by
repeatedly pressing the button programmed as "coded actuator",
it is possible to cycle through ONLY the cameras connected to Art.
1409 with the corresponding address.
„ To activate the function, program the button on the monitor as
ON
coded actuator (with address between 220 and 227 inclusive) and
set selector "S1" as illustrated in the table below:
S1
DIP 1 DIP 2 DIP 3 DIP 4 DIP 5 DIP 6
1
0
0
1
0
1
1
0
0
1
0
1
1
0
0
1
0
1
1
0
0
1
0
1
Up to 8 modules Art. 1409 with 8 different codes can be installed in
the same system.
S1
1409 address-coded actuator
correspondence
Address
Actuator code
1409
on monitor
0
0
0
0
0
0
0
1
1
0
0
2
1
0
0
3
0
1
0
4
0
1
0
5
1
1
0
6
1
1
0
7
Example for setting address on Art. 1409
for control by means of actuator code 224
220
221
222
223
224
225
226
227