Controls And Indicators; Inspections Before Starting; Starting And Stopping The Vacuum Cleaner; Operation - Blastrac BDC-22-110V Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Instruction manual BDC-22-110V

Controls and indicators

Figure 4
1.
Main motor Start/Stop switch
You can start/stop the main motor with this switch.
2.
Second motor Start/Stop switch
You can start/stop the second motor with this switch.
3.
Vacuum gauge
4.
Manual filter shaker lever

Inspections before starting

Figure 5
1.
Inlet
Before starting, check that:
The filters are installed;
The closing band is properly tightened;
The vacuum hose and tools have been correctly fitted into
the inlet (1);
bag (2, Fig. 1) is installed.
The Longopac
®
WARNING!
Lock the caster brakes before starting the vacuum
cleaner (2).
WARNING!
Do not use the device if the filters are faulty.

Starting and stopping the vacuum cleaner

Figure 4
Toggle the switch (1) to the "ON" position to start the first
motor.
Toggle the switch (2) to the "ON" position to start the
second motor.
Toggle the switch (1) to the "OFF" position to stop the first
motor.
Toggle the switch (2) to the "OFF" position to stop the
second motor.

Operation

Figure 7
Vacuum gauge (2): green zone (3), red zone (1)
When using the vacuum cleaner, check the flow control:
when the vacuum cleaner is operating, the pointer of
the vacuum gauge must remain in the green zone (3)
to ensure that the speed of the intake air does not drop
below the safety value of 20 m/sec;
If the pointer is in the red zone (1) it means that the speed
of the air in the vacuum hose is less than 20 m/s, and that
the vacuum cleaner is not operating in optimal conditions.
Shake or replace the filter.
during normal operation conditions, close the vacuum
hose, the pointer of the vacuum gauge must switch from
the green zone (3) to the red zone (1).
WARNING!
When the vacuum cleaner is operating, always check
that the vacuum gauge pointer remains in the green
zone (3).
Consult the "Troubleshooting" chapter if faults occur.
WARNING!
The air speed in the suction tube must not be less than
20 m/s.
Condition indicated by the vacuum gauge pointer in the
green zone (3).
WARNING!
All vacuum cleaners can be used only with hoses
whose diameters comply with the specifications in the
"Technical Data" table.
WARNING!
Consult the "Troubleshooting" chapter if faults occur.
www.blastrac.com ‒ info@blastrac.com
7/16
I
US

Publicidad

Tabla de contenido
loading

Tabla de contenido