Descargar Imprimir esta página

Optimus IA-20SIP Guía Rápida página 3

Publicidad

Idiomas disponibles

Idiomas disponibles

QUICK GUIDE
SPECIFICATIONS
1.
Relay output contact. The contact is activated when it receives a DTMF tone previously programmed. Max 24 V, 2 A.
2.
PRI output contact. Open collector. It remains activated while call is active.
3.
Microphone Audio Output -60 dB.
4.
Aux Audio Output 0 dB.
5.
Speaker audio output 8 Ohm 2 W.
6.
Power supply input 5 Vdc.
7.
Micro/Aux audio input and call activation contact. When the Contact is closed equipment starts a call (by pulse or level according
to the configuration).
8.
Micro/Aux switch. Select ON, ON for Microphone, or OFF, OFF for Aux.
9.
Ethernet POE connector.
10. Power indicator Led.
11. Calling Led. It will blink during call establishment and it remains lit when cal is successful.
12. Audio output Led. Audio output level indicator.
IA-20SIP Version 1.3
IA-20SIP
ATTENTION:
1/2
IP SIP AUDIO INTERFACE
⋅ Make sure the power source conforms to the power
requirements before connecting the equipment.
⋅ Do not install the unit near heat sources.
⋅ Only qualified service personnel should be allowed to
install and operate the unit.
Power supply
Consumption
Dimensions
Weight
Finish
Black painted iron RAL9005
Z-112 Rack mounting kit for 1 unit
Accessories
(not included)
Z-113 Rack mounting kit for 2 units
POE / 5 Vcc
10 W Máx.
214 x 105 x 41 mm
0,8 kg

Publicidad