Settings
The programmer's stand:
®
The PayMatic
can be programmed by means of the two operating buttons
which are integrated into the front panel of the coin operated timer. By using
these operating buttons and the key switch next to it the functions can be
programmed, modified or read. The operating buttons are identified by means
of little square marks.
Programming the 14 functions in the timer can be carried out by following the procedure set out below:
1.
Turn the key switch to the horizontal "service" position to release the buttons;
2.
Activate the function register by pushing the "up" and "down" buttons, the display shows F1;
3
Select the required function register by using the "up" an "down' buttons;
4
Activate the selected function register by pushing both buttons at the same time;
5
Read out the function, or change the set up with the "up" and "down" buttons;
6
To leave the selected function register, push both buttons at the same time;
7.
To leave the function register, go back to function F0 and push both buttons at the same time;
8.
Turn the key switch to the vertical OFF-position.
Function overview
Function F0, Quitting the function menu
Choosing this function the PayMatic
Function F1, Main time setting per coin
Main time setting for relay 1 per coin given. In the standard version this setting may vary from 1 to 15
minutes. By adding "ECOS"
minutes is programmed the indication will be displayed intermittently in two parts; first display "1",
second display "00".
Function F2, Prior time setting
Before starting the main time, relay contact 2 shall be closed. This setting is programmable up to a
maximum of 255 minutes.
Function F3, Post time setting
At the end of the main time, relay contact 2 shall be closed. This setting is programmable up to a
maximum of 255 minutes.
Function F4, Maximum amount of coins
Maximum amount of coins that can be activated to increase cumulatively the total main time. The value
of this setting has to be at least 1.
®
will remain in stand-by to be able to program or to quit the menu.
(ECOS module EM-01)
®
up to 255 minutes can be programmed. If a value of more than 100
(ECOS module EM-02)
(ECOS module EM-03)
(ECOS module EM-04)
®
PayMatic
AD2400(-B) Version 2.0 5-11-2007
-
www.inepro.com
-
Up
Down
14