1
Mark wall at desired location for mounting J-rail. Use dimension
"X" as shown on table of page 1 for locating the correct ceiling
to mounting hole location. Using J-rail as a template, mark hole
locations along wall for pre-drilling where needed. Secure J-rail to
wall. Hardware, bracing, and other structural support for J-rail to be
supplied and installed by contractor as needed. J-rail hole diameter
is ¼" so #12 screws recommended. J-rail hole diameter is ¼" so
#12 screws recommended.
3
FOR FSR ONLY: Using (2) 8-32 screws from the LED pan assembly,
install aperture guide snugly to ensure housing opening does not
open or close during installation.
5
Each fixture length, Individual or Continuous, is supplied with a
pre-wired remote driver enclosure. Enclosure can be dis-connected;
ensure to mark enclosure and fixture if dis-connected. Remote
enclosure is supplied with MAXIMUM length low voltage, plenum
rated cable. Cable can be shortened if desired. DO NOT lengthen
cable.
3
EATON
IL519013EN
Installation instructions
2
LOW VOLTAGE
DISCONNECT
Prior to installing fixture, remove lens and diffuser bracket. Turn
fixture over. Remove screws and carefully lift LED pan assembly
from housing frame, disconnect low voltage connection and store
pan assembly in a safe place.
4
Locate remote driver in an accessible location. Either an access
panel or other accessible location may be needed to service driver
after final installation.
6
Bring power to remote enclosure. Remove access plate, make
appropriate wire connections and re-secure access plate to remote
enclosure. Lift fixture onto J-rail via perimeter brackets on side of
fixture.