Clearances - Empire SR-6-3 Instrucciones De Instalación Y Manual Del Propietario

Calentador de gas para habitaciones
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

24" MIN
(610mm)
14" MIN
(356mm)
6" MIN
(152mm)
2" MIN
(51mm)
Figure 5 (SR-10)
When facing the front of the appliance the following minimum
clearances to combustible construction must be maintained.
Left side 6 inches (152mm). Right side 6 inches (152mm).
Do not install in alcove or closet.
Rear wall 0 inches (0mm). Ceiling 36 inches (914mm).
Minimum vertical clearance from a projection above the
appliance (shelves, window sills, etc.) 36 inches (914mm).
Floor (top surface of carpeting, tile, etc.) 2 inches (51mm).
Provide adequate clearances around air openings.
Adequate accessibility clearances for purposes of servicing and
proper operation must be provided.
16942-3-0506
CEILING
SIDE WALL
6" MIN
(152mm)
FLOOR
SR-18 CLEARANCES
WINDOW SILL OR SHELF
24" MIN
(610mm)
14" MIN
0" (0mm) CLEARANCE
(356mm)
TO REAR WALL
SIDE VIEW
2" MIN
(51mm)
Figure 6 (SR-10)
CEILING
SIDE WALL
36" (914mm) MIN
6" (152mm)
MIN
2" MIN
(51mm)
Figure 7 (SR-18)
CEILING
12" MAX
(305mm)
FLOOR
6" (152mm)
MIN
FLOOR
Page 9