Drain And Tailpiece; Faucet Battery Box; Adjust Temperature With Water Running - Bradley Frequency FL-1H Manual Del Usuario

Sistema de lavabo
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

FL-1H, FL-1L
3

Drain and Tailpiece

FL-1H
Rubber
Friction
Nut
4

Faucet Battery Box

FL-1L shown
FL-1H is similar
A
Mount the Faucet Battery
Box to the wall at the
desired location.

Adjust Temperature with Water Running

5
This valve is NOT factory preset.
Upon installation, the temperature
of this valve must be checked and
adjusted to ensure delivery of a
safe water temperature. Water
in excess of 110°F (43°C) may
cause scalding.
8
Tailpiece
Faucet Valve
Control Module
A
Loosen Cap Screw about 1/4" (4-6
turns) and lift up cover (do not
remove).
B
Using cover, turn cartridge gently until
desired water temperature is reached.
Do not turn past stops as this may
damage unit. Push cover down and
tighten screw.
11/26/2019
FL-1L
Rubber
Friction
Nut
Flexible Hose (qty. 3)
Mixing Valve
Hot
Cold
Stop Valve
Bradley Corporation • 215-1511 Rev. G: ECO 19-08-035
Installation
Tailpiece
4" (102mm)
B
Install the faucet according to
manufacturer's instructions.
H