Warnings
• For personal safety it is important to observe all instruc-
tions herein and conserve this document for future consul-
tation.
• This manual contains important safety instructions for
installation. Incorrect installation procedures may lead to
seriously hazardous conditions.
• Partial reading of these instructions will not ensure that the
user exploits the characteristics of this product to the full.

1) Product description

The TT2N control unit enables the control of a single phase asyn-
chronous motor, mains powered, with connection types: Down,
Common, Up, used for the automation of awnings, rolling shutters
and similar.
The TT2N control unit incorporates a radio receiver that operates at
the frequency of 433.92 MHz with rolling code technology to guar-
antee optimal safety levels.
Each control unit can memorise up to 30 transmitters in the series
ERGO, PLANO and NICEWAY (figure 1), which enable the remote
control of the unit. In the 30 transmitters, a maximum of 3 VOLO S
RADIO climatic radio sensors can be memorised, for the automatic
control of the control unit according to weather conditions.
After each command the motor is powered for approx. 150 sec-
onds; this time interval can be modified (chapter 4.3 Work time). Dur-
ing this interval, the electric limit switch in the motor stops movement
at the set position.
The control unit is equipped with an input "P/B" for control of the unit
also by means of and external pushbutton.
Memorisation and programming is possible via the transmitters or
direct via the programming pushbutton (figure 2) on the TT2N. The
user is guided through the various phases by means of led signals.
1
ERGO
2) Installation
• The product is subject to hazardous electric voltages
• The installation of the TT2N and automations must be
performed exclusively by technically qualified person-
nel, in observance of current legislation and standards,
and according to these instructions. All connections
must be made with the system disconnected from the
power supply.
• The TT2N control unit has been especially designed for
insertion in a junction box or wall box; its housing does

2.1) Preliminary checks

• The power supply line must be protected by suitable magne-
tothermal and differential switches.
• A disconnection device must be inserted in the power supply line
from the electrical mains (the distance between the contacts must
be at least 3.5 mm with an overvoltage category of III) or equivalent
2
The TT2N has been designed for control of a single phase asynchronous
motor, mains powered, used for the automations of awnings, rolling
shutters and similar devices; any other use is improper and strictly pro-
hibited. Installation must be carried out by qualified technical personnel
in full compliance with current legislation and electrical and safety stan-
dards.
Note. The TT2N control unit can also manage other types of trans-
mitter and other operating modes; refer to chapter 4 "Further
Details".
2
PLANO
not feature any protection against water and only basic
protection against contact with solid parts. Never place
the TT2N in inadequately protected environments.
• Never open or perforate the TT2N housing; do not cut
the aerial cable under any circumstances: this is subject
to hazardous electric voltages!
system, for example an outlet and relative plug. If the disconnec-
tion device for the power supply is not mounted near the automa-
tion, it must have a locking system to prevent unintentional, unau-
thorised connection.