KEY TO SYMBOLS

Parts to read carefully.
Parts about safety.
ER:
end run.
Moving part: awnings, shutters and blackout systems
unless otherwise indicated.
The number of "click-clacks" at the end
of the sequence corresponds to the tilting
movements the motor performs to provide a
visual indication that the procedure has been
accepted by the receiver.
Maximum time to perform the procedure
from when the power supply is connected.
1'
BEFORE INSTALLATION
- Do not allow children to play with the Transmitter.
- Make sure to stay clear of the moving element until it has
completely stopped.
- Frequently check the system for any signs of
unbalancing, of wear and tear or damage.
- To clean the moving element, cut off the power supply
to the motor.

INTENDED USE

Receiver unit for motors with single-phase asynchronous
electromechanical end run, mains-powered and intended
for automating awnings, shutters and the like.
Compatible with all the transmitters from the KLT series that
work at the same frequency.
Any installation and operation that diff ers from what
is set out in this manual is prohibited.
Technical data
KLT-W50
Maximum motor power
500 W / 400 VA
Operating temperature
0°C / +55°C
Power supply
230 V AC ± 5% 50 Hz
Reception frequency
433,92 MHz / 868.35 MHz
Manoeuvre duration
4 min.
Cable type and cross-section
Powering the panel and
Connection
connecting the button
Cable type
EN 50267-2-1
Cable length 1 < 10 m
3G x 0,75 mm
Cable length 10 < 20 m
3G x 1 mm
Cable length 20 < 30 m
3G x 1.5 mm
Connection
Motor power supply
FR0R CEI 20-22 CEI EN
Cable type
50267-2-1
Cable length 1 < 10 m
4G x 0.75 mm
Cable length 10 < 20 m
4G x 1 mm
Cable length 20 < 30 m
4G x 1.5 mm
INSTALLATION
Installation must be carried out by qualifi ed and
experienced personnel in compliance with applicable
regulations.
All connections must be made while the electrical
power is disconnected.
The unit may be disturbed as it is sensitive to external
elements, such as masses, metal roofing and
electromagnetic fi elds or radio broadcasts at the same
frequency, which can impair unit operation. Use plastic
containers and position the antenna away from power
cables.
- Connect the wires to the terminal, respecting the
diagram in Fig.
Connections" chapter.
The container should not be pierced for any reason.
Antenna
For normal operation, the unit is equipped with an antenna
in the form of a 17 cm insulated cable.
Under no circumstances cut or change the antenna
cable.
Preliminary checks
The unit can be inserted inside a fl ush box or a shock-
resistant junction box.
2
Prepare suitable piping and ducts for routing the
2
electrical cables, ensuring protection against
2
mechanical damage.

ELECTRICAL CONNECTIONS

Do not connect more than one motor for each unit.
2
Respect the envisaged connections.
2
Improper connection may cause serious damage to
2
the unit.
Mains power supply
blue (common)
brown (phase)
Motor power supply
blue (common)
brown (phase)
Use a switch button with central zero and automatic
return.
and the instructions in the "Electrical
earth
black (phase)
earth
119T70541 - ver. 2 2 - 03/2013