Putting Into Operation - CAME RKLT-W50 Manual De Instrucciones

Ocultar thumbs Ver también para RKLT-W50:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 14
Once the electrical connection has been made,
check that the direction of rotation of the motor is
as required. If it is not, invert the brown wire
the black one
.
AUTOMATIC operating mode
AUTOMATIC operating mode
moving part opens or closes completely.
HOLD-TO-RUN mode
Each time the
/
button is pressed, the moving part
moves by 1/10 of a revolution (about 36°).
When a button is held down for more than 2", the motor
switches temporarily into automatic mode until the fi rst stop,
then switching back to hold-to-run mode.

PUTTING INTO OPERATION

All the memorised sequences are timed.
When powered, the unit beeps and makes the motor
move if no transmitters are memorised. Otherwise, it
beeps only.
In addition to the radio control, the unit can also be controlled
by an external button that is activated after storing the 1st TX.
When pressed once, the motor begins to move in the chosen
direction. Pressing the same button again or the one for the
opposite direction stops the motor.
Storing the Tx
Act within a minute of having powered the motor.
Any other motors or virgin accessories in the range of
action of the TX must not be powered.
Adjusting the ERs on the shutters
and
To adjust the ER points, use the adjustment rod or a
4 mm hex head screwdriver.
- Release the shutter from the roller tube.
- Move the tube without the roller shutter downwards until
/
is pressed, the
the motor comes to a stop on its own.
- Holding down the button, turn the lower ER adjustment
screw towards (+) until reaching a suitable position to
couple the belt.
- Attach the shutter to the tube.
- Control of the ascent of the shutter until the motor stops.
I
F IT EXCEEDS THE REQUIRED UPPER POINT
movement, move the shutter under the required stopping
point and adjust the ER by turning the adjustment
screw towards (-).
I
F IT STOPS AT A POINT BELOW
adjustment screw towards (+) until the shutter reaches
the required position.
Adjusting the ERs on awnings
Adjust the ER with a margin of safety, considering
the changes in size of the material due to weather
conditions.
After a few days of operation, check the installation
and adjust the ERs again if necessary.
Automatic/hold-to-run mode
Deleting all the memorised TXs
In order to delete all the memorised TXs, refer to the fi gure
or hold down the unit programming button for 10" .
This procedure will delete all the TXs and the direction
of rotation in the memory.
The buttons remain active to move the moving part
until the fi rst time the electricity is disconnected.
Memorising an additional TX (2
In order to memorise a second TX, refer to Fig.
the unit programming button briefly, wait for the beep and
press UP on the TX to be memorised.
A maximum of 20 TXs (including weather stations and/or
timers) can be memorised.
required, stop the
Stament CE of compliance -
S.p.A. declares that this device is compliant with the essential
requirements and other pertinent measures established
that required, turn the ER
by directives 2006/95/EC, 2014/30/UE, 1999/5/EC.
Reference code to request an original copy: DDC RA H008.
Dismantling and disposal -
a good idea to check your local legislation on the matter. The
components of the packaging (i.e. cardboard, plastic, etc.)
are solid household waste and may be disposed of without
diffi culty, by simply throwing them out in the corresponding
recycle bins. Other components (i.e. control boards, radio
transmitter batteries, etc.) may contain hazardous substances.
These must therefore be handed over to specially authorised
disposal fi rms.
DISPOSE OF CAREFULLY!
The data and information in this manual may be changed at any time
and without prior notice.
After deletion, wait 10" before performing other
operations.
TX MANAGEMENT
nd
)
If you attempt to add 21 TXs, the unit beeps 5 times
in a row, indicating that the memory is full.
Came Cancelli Automatici
Before proceeding it is always
119T70541 - ver. 2 2 - 03/2013
119T70541
or press

Publicidad

Tabla de contenido
loading