Important - Dyna-Glo RMC-FA40DGD Manual De Instrucciones Del Usuario

Calentadores de propano de construcción
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Dyna-Glo Propane Forced Air Construction Heaters
The heater is designed and approved for use as a construction heater under ANSI Z83.7., CSA2.14
It is hard to anticipate every use which may be made of this heater.
FIRE SAFETY AUTHORITY IF YOU HAVE QUESTIONS ABOUT APPLICATIONS.
Other standards govern the use of fuel gases and heat producing products in specific applications.
Your local authority can advise you about these.
IMPORTANT: Read this user's manual carefully and completely before trying to operate or
service this heater. Improper use of this heater can cause serious injury or death from fire,
explosion and carbon monoxide poisoning.
This is a direct-fired forced-air construction heater for either indoor construction or outdoor use.
Its intended use is primarily the temporary heating of buildings or structures under construction,
alteration or repair. All the products of combustion generated by the heater are forced through the
heater and released into the area being heated. This heater operates at approximately 98%+ combustion
efficiency but still produces a small amount of carbon monoxide. Humans can tolerate small
amounts of carbon monoxide for short periods. Carbon monoxide can build up in a heated space and
failure to provide adequate ventilation could result in poisoning or death.
WARNING: Not for use with ductwork.
SPECIFICATIONS:
Model No.
Input Rating
Type of Gas
Gas Supply Pressures
to Regulator Maximum
Minimum (for purpose
of Input Adjustment)
Manifold Pressure
Gas Consumption
Electrical Input
Amperage
Load
Unload
Fan
Load
Ignition
Spark Gap
Size (L x W x H)
Weight
RMC-FA40DG/
RMC-FA50A/C/L
DGD/DGP/DGP-01
RMC-FA50DG/DGD
RMC-FA50DGP-01
RMC-FA40
40,000 BTU/hr
30,000 BTU/hr
-
50,000 BTU/hr
Propane
Propane
Cylinder Pressure
Cylinder Pressure
5psig
5psig
11" W.C
11" W.C
1.9lbs/hr
1.4lbs/hr
2.3lbs/hr
120V, 60Hz, 1 Ø
120V, 60Hz, 1 Ø
0.68amps
0.65amps
3550rpm
3570rpm
3000rpm
3300rpm
Piezo/Manual Spark
Continuous Spark
0.16"
0.16"
18.1" x 8.1" x 15.3"
18.1" x 8.1" x 15.3"
13.7lbs/14lbs
14.3lbs (6.48kg)
(6.2kg/6.35kg)
CHECK WITH YOUR LOCAL
RMC-FA100A/C/L
RMC-FA150DG/DGD
RMC-FA100DG/
RMC-FA150A
DGD/DGP/DGP-01
70,000 BTU/hr
120,000 BTU/hr
100,000 BTU/hr
150,000 BTU/hr
Propane
Propane
Cylinder Pressure
Cylinder Pressure
5psig
5psig
11" W.C
11" W.C
3.3lbs/hr
5.6lbs/hr
4.6lbs/hr
7.0lbs/hr
120V, 60Hz, 1 Ø
120V, 60Hz, 1 Ø
0.7amps
0.7amps
3580rpm
3580rpm
3300rpm
3300rpm
Continuous Spark
Continuous Spark
0.16"
0.11"
25" x 12.8" x 16"
25" x 9" x 16.9"
25" x 9" x 16.9"
25" x 11.6" x 17.3"
21.5lbs/21lbs/20.8lbs
21.2lbs (9.6kg)
(9.75kg/9.5kg/9.4kg)
Page 2

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Rmc-fa150dgd

Tabla de contenido