Liberty Pumps LSG202A Manual De Instalación página 9

Bombas de saneamiento y trituradora omnivore
Ocultar thumbs Ver también para LSG202A:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

SYMPTOM
1.
PUMP WILL NOT START
2.
REPEATED TRIPPING
3.
PUMP WILL NOT SHUT
OFF
4.
LOW FLOW
5.
WATER IN OIL CHAMBER
6.
WATER
INSIDE
MOTOR
CASING
IF SYMPTOMS CONTINUE, CONSULT THE LIBERTY PUMPS PRODUCT SERVICE DEPT.
©Copyright 2008 Liberty Pumps Inc. All rights reserved
TROUBLESHOOTING CHART: LSG200
POSSIBLE CAUSE
A.
Power supply failure
B.
Burned out fuse or tripped circuit
breaker
C.
Damaged power cable
D.
Jammed impeller
E.
Water inside motor
A.
Circuit protection under-rated
B.
Current unbalance
C.
Pump
connected
to
voltage
D.
Wet or damaged wiring
E.
Obstruction in pump
F.
Incorrect motor rotation
G.
Foreign matter build-up
A.
Control panel failure
B. Switch Failure
A.
Incorrect pump rotation
B.
Low liquid level
C.
Obstruction in pump or piping
D.
Partially closed valve(s)
A.
Loose or damaged oil plug
A.
Damaged
lower
lip
mechanical seal
B.
Damaged
O-Ring
between
chamber and motor plate
C.
Damaged cable
ACTION
A.
Check power supply
Check out electrical system for
loose connections
Check operating voltage
B.
Check circuit protectors
C.
Check external cable for damage
– repair
D.
Inspect and remove jamming
object
E.
Refer to Symptom 5 and 6
A.
Check rating and replace with
proper size
B.
Check current draw
incorrect
C.
Verify connections.
diagram
D.
Inspect external cable, replace if
worn or damaged
E.
Remove obstruction
F.
Check rotation
A.
Clean motor housing
B.
Check control panel
C.
B. Replace the switch
A.
Check rotation
B.
Check liquid level
C.
Remove obstruction
D.
Check and adjust valve
A.
Check plug and sealing washer
seal
or
A.
Replace seal
oil
B.
Replace O-Ring
C.
Replace cable
See wiring
- 9 -

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Lsg202mLsg203mLsg204mLsgx202aLsgx202mLsgx203m ... Mostrar todo

Tabla de contenido