13. This heater is shipped from the factory for use with LP (propane) gas only. Do not convert to any other
gas. Installation must conform to local codes, or in their absence, with the standard for the Storage and
Handling of Liquefied Petroleum Gases ANSI/NFPA 58.
14. Use only the regulator and hose assembly provided with this heater. Inspect the regulator/hose assembly
prior to each use of the heater. If there is excessive abrasion or wear, or if the hose is cut, replace it with
the proper assembly shown in the parts list, prior to using the heater.
15. Gas supply connections should be checked by using a 50/50 soap and water solution. Never use a flame
to check for gas leaks.
16. Locate LP cylinder at least 6 feet from the heater, and do not direct heater discharge towards the LP cylinder
unless it is at least 20 feet from the heater.
17. The electrical connection and grounding must comply with the National Electrical Code, ANSI/NFPA 70.
Use only a properly grounded three (3) prong receptacle.
18. Do not restrict air inlet or outlet areas of the heater.
19. When used with optional thermostat heater may start at anytime.
20. Do not use heater outdoors or in occupied dwellings.
21. Do not adjust regulator below 7 PSIG or above 18 PSIG.
22. Use only original replacement parts. This heater must use design-specific parts. Do not substitute or use
generic parts Improper replacement parts could cause serious or fatal injuries.
23. Do not alter heater. Keep heater in its original state.
24. Do not use heater if altered.
25. Keep propane tank(s) below 100°F
26. Turn off the gas supply at the cylinder when the heater is not is use
WARNING: NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A