Descargar Imprimir esta página

Teka DQ-90 Manual De Instrucciones página 13

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

A A c c c c e e s s o o r r i i e e s s s s u u p p p p l l i i e e d d
1
150/ 120 mm reduction.
2
Support for tubecover.
2
Wall support.
6
Wall plugs (Ø8 x 40).
6
Long bolts (Ø5 x 45).
4
Wall plugs (Ø6 x 30).
4
Long bolts (Ø4 x 30).
2
Ø6,4 x Ø18, washers.
2
Ø6,4 x Ø12, washers.
2
Screws (Ø3,9 x 13).
4
Screws (Ø4 x 12).
2
Clips.
I I n n s s t t a a l l l l a a t t i i o o n n
O O n n i i n n s s t t a a l l l l i i n n g g t t h h e e k k i i t t c c h h e e n n h h o o o o d d m m a a k k e e s s u u r r e e
t t h h a a t t t t h h e e S S a a f f e e t t y y I I n n s s t t r r u u c c t t i i o o n n s s s s e e t t o o u u t t o o n n
p p a a g g e e 1 1 0 0 a a r r e e c c o o m m p p l l i i e e d d w w i i t t h h . .
To obtain optimum performance, the external
conduct must not be more than FOUR
METRES long, have no more than two 90°
angles and its diameter must be at least Ø120.
F F i i g g . . 1 1 a a ( ( P P a a g g e e 3 3 1 1 ) )
1) Trace and drill the points for fitting the wall
plugs onto the wall (P) (Ø8 x 40), (J) and (E)
(Ø6 x 30).
2) Attach the Supports (O) to the wall using the
long bolts (Q) (Ø5 x 45) and the supports (H)
and (C) with the long bolts (I) and (D) (Ø4 x 30).
F F i i g g . . 1 1 b b ( ( P P a a g g e e 3 3 1 1 ) )
3) Fit the clips (F) to the support (C).
4) Remove the metal filters. Loosen the screws
(without unscrewing them) of the EASYCLEAN
panels (A19), move the panels aside carefully
and take them off.
5) Hang the kitchen hood onto the mounted
supports (O). Straighten the appliance by
tightening the long bolts (L) (M4 x 12), as per
the detail in figure 1b.
6) Trace the location of the wall plugs (R) (Ø8
x 40) through the inside of the kitchen hood.
7) Drill into the wall and fit the wall plugs (R)
(Ø8 x 40) and tighten he long bolts (S) (Ø5 x
45) with the washers (T) (Ø6,4 x Ø18).
8) Fit the part (B) if the inner tube (not supplied)
is Ø120.
9) Attach the inner tube with a clamp (not
supplied) to (B) or on to the motor's air outlet
vent as the case may be.
10) Loosen the screws (U) (M4 x 25) the lower
tubecover. Once the inner tube is fitted, mount
the tubecovers, attaching the lower one to the
support (H) as per the detail in figure 1b.
11) Attach ubecover around with the screws
(U) (M4 x 25) through the inside of the kitchen
hood. Lift and attach the upper tubecover with
the screws (G) (Ø3,9 x 13).
12) Mount the EASYCLEAN panel again (A19).
Fit the metal filters.
A A c c t t i i v v e e c c h h a a r r c c o o a a l l f f i i l l t t e e r r s s ( ( O O p p t t i i o o n n a a l l ) )
When exterior gas extraction is not possible,
then the kitchen hood may be set to purify the
air by recycling it through active charcoal
filters.
The active charcoal filters have an active life of
between three to six months, depending on
the individual conditions of use. These filters
cannot be washed nor regenerated. They must
be replaced once their useful life comes to an
end.
F F i i g g . . 3 3 ( ( P P a a g g e e 3 3 1 1 ) )
1) Remove the metal filters. Loosen the screws
(without unscrewing them) of the EASYCLEAN
panels (K), move the panels aside carefully
and take them off.
2) Remove the screws (U) (M4 x 25) and the
tubecovers (H). Fit the nut-supports (G) to the
diffuser (C).
3) Fit the diffuser (C) into the inside of the lower
tubecover (H) with the screws (D) (M4 x 12).
Mount the tubecovers (H) with the screws (U)
(M4 x 25).
4) Put the filters into the lateral draught section
of the motor making the holes in the filters
match up (A) with the pivots (B) of the motor
carcass. Turn as indicated in the diagram.
5) Mount the EASYCLEAN panel again (K). Fit
the metal filters.
13