Concrete Encounter CME4

Operating Instructions

A diagram of the instrument face with brief notes on the
push button controls and LED indicators is shown below.
Moving coil meter
LED indicators show:-
1. Power on.
2. Hold – flashing LED.
3. Low battery - LEDs
flash sequentially.
Hold – flashing LED
Power On LED
Power ON/OFF button.
Automatic switch off
after 10 minutes if :-
1. No button pressed.
2. No change in meter
reading.
HOLD button
Press once for HOLD
Press again to remove
HOLD
1. Press the ON/OFF button to power up. The lower LED
will light. [Note – If the battery voltage is getting low, the
two LEDs will flash sequentially for a short period. The
instrument will continue to operate for some time but it is
recommended that the PP3 (9 volt) battery be replaced as
soon as convenient.]
2. Press your Concrete Encounter CME 4 directly onto the
surface of the material being tested ensuring that all of
the electrode spring loaded pins are fully compressed.
3. For concrete, read the moisture content from the top, 0%
to 6%, scale of the meter dial. Readings on a concrete
floor slab obtained on this scale indicate moisture
content measurement and should not be confused with
lbs emission or any other unit of measurement obtained
by other moisture testing methods or meters. It should
User Guide
CONCRETE ENCOUNTER
ON/OFF
6
CONCRETE
%H²O
Concrete
GYPSUM
Encounter
FLOOR
SCREED
CME 4
HOLD
CME4/0908