*P519-095*
P519-095
Mullion Reader
1
Separate case from baseplate.
Baseplate
2
Mark and drill holes.
L NOTE: Drill and tap for mounting on metal surface. Use
Z\," (3 mm) holes for mounting on wood, or appropriate
anchors for other surfaces.
Drill
1" (25 mm)
MTB11
Support and Warranty
us.allegion.com
(877) 671-7011
+1 512-712-1316
Allegion Address
3899 Hancock
Expressway
Security, CO 80911
Case
Drill and tap
6-32 hole
MTB11
Tools
•
Phillips Screwdriver
•
6-32 Tap
•
1" (25 mm), Z\," (3 mm) Drill Bits
•
T10 Security Torx Screwdriver (Optional)
3
Wire the cable to the control module.
Wiring methods shall be in accordance with the National Electrical Code
(ANSI/NFPA70), CSA 22.1, Canadian Electrical Code (CEC), Part I, Safety
Standard for Electrical Installations, local code, and the authorities having
jurisdiction. A shielded cable must be used.
A power limited, class 2 UL 294 approved power supply must be used.
Voltage rating 5VDC to 28VDC.
Gauge to power supply
Total length
(power & ground wires)
to power supply or
Power supply voltage
to panel
12 VDC
100 ft (30.5 m)
22
200 ft (61 m)
22
300 ft (91.5 m)
20
400 ft (121.9 m)
18
500 ft (152.4 m)
18
600 ft (182.9 m)
18
700 ft (213.4 m)
18
800 ft (243.8 m)
16
900 ft (274.32 m)
16
1000 ft (305.8 m)
Estimated Current Draw
Input Voltage
Avg.
Max.
(VDC)
mA
mA
5
145
310
12
80
190
24
45
100
28
40
The max run for a 5V supply is 50 ft (15 m) with 18 AWG.
*
Tamper Outputs are to be connected to a UL-Rated Burglary System.
Installation Instructions
For Indoor/Outdoor Use
Mobile Enabled Multi-
Technology Reader -
Mullion
Gauge to panel
(all other wires)
24 VDC
22
22
22
22
20
20
20
18
18
-
18
Cable Connections
Ground
Black
Unused
Blue
Red LED Control
Brown
Tamper Out
Gray*
Wiegand Data 0 / Data
85
Green
Green LED Control
Orange
RS485-A/Y
Pink
Power In
Red
Shield Ground
Shield
RS485-B/Z
Tan
White
Wiegand Data 1 / Clock
Yellow
Beeper Control
22
22
22
22
22
22
22
22
22
22