OPERATING INSTRUCTION
Checking for leaks
WARNING
Perform all leak tests outdoors.
•
Extinguish all open flames.
•
NEVER leak test when smoking.
•
Do not use the heater until all connections have been leak tested and do not
•
leak.
Your patio heater has been checked at all factory connections for leakage. To
check the connection at the gas hose/ regulator/ cylinder:
a. Make leakage solution by mixing 1 part liquid dish soap and 3 part water.
b. Spoon or brush several drops (or use squirt bottle) of the solution onto the gas
hose/regulator and regulator/cylinder and hose connection.
c. Turn on gas cylinder valve. Inspect the connections and look for bubbles.
1. If no bubbles appear, the connection is safe.
2. If bubbles appear, there is leakage. Loosen and re-tighten this connection. If it
still leaks, please call customer service at: 1-888-287-0735 .
Lighting Instructions
1. Turn the LP gas tank valve OFF. Push the control knob in, turn OFF, and wait 5
minutes for any gas to clear.
2. Turn the tank valve ON. Push control knob in and rotate to PUSH. And, push the
igniter button until the burner is ignited. If igniting the burner
for 5 seconds continuously but the burner fails to remain lit or becomes
extinguished, repeat step 2 after 5 minutes. Complete shutoff period
before relighting.
3. Once the burner has lit, continue to hold the control knob in for 30 seconds, and
then release.
4. Turn the control knob from HIGH to LOW to the desired heat setting.
For complete shutdown
1.Please turn the knob to "PUSH" position first, then push and turn to "OFF" position
for complete shut off.
2.Turn the LP gas tank value OFF before remove the LP gas tank.