Littelfuse POWR-GARD PGR-6150 Serie Manual De Instrucciones

Publicidad

Enlaces rápidos

POWR-GARD
®
• MOTOR PROTECTION SYSTEM
• SISTEMA DE PROTECCIÓN DE MOTOR
• SYSTÈME POUR LA PROTECTION DES MOTEURS
1
2
3
1
2
3
4
5
DIG IN
GF CT
L1
L2/N
POWR-GARD
MOTOR PROTECTION SYSTEM
PGR-6150 SERIES
PGR-6150 SERIES
ON
FLASHING
O/L, JAM,
UNDER-
1
LCKD ROTOR
CURRENT
EXT ST TIME
GROUND
2
OPEN CT
FAULT
PWR
1
2
OVERTEMP
3
PTC FAILURE
RESET
PHASE
4
UNBALANCE
SEQUENCE
RS-485
K1
K2
12
14
11
22
24
21
10
5
6
For detailed operating
instructions consult the
PGR-6150 manual available
at www.littelfuse.com
• DIMENSIONS
L3
L1
PGR-6150 SERIES • Country of origin: Spain • SEPTEMBER 17, 2010 • 1-800-TEC-FUSE (1-800-832-3873) • www.littelfuse.com
PGR-6150 SERIES
4
1
2
6
7
8
3
PTC
4
5
9
6
10
7
3
4
8
8
9
10
9
PWR
7
1
2
3
4
On
L2
Supply
Alimentación
Digital input
Entrada digital
Toroidal Transformer
Transformador toroidal
PTC Sensor
Sonda PTC
Trip Contact NO-NC
Contacto disparo NA-NC
Alarm Contact NO-NC
Contacto alarma NA-NC
RS-485 Modbus RTU
RS-485 Modbus RTU
RESET Button
Botón de REARME
RJ45 Connector
Conector RJ45
Trip/Alarm LED's
LEDs de disparo/alarma
Relay OK
Equipo OK
Overload/Jam/Locked Rotor/
Sobrecarga/Jam/Rotor bloqueado/
Excessive Start Time
Arranque
Undercurrent
Subintensidad
Ground Fault Internal/External
Falta a tierra homopolar/diferencial
Toroidal CT Connection Alarm
Alarma conexión CT toroidal
Overtemperature (PTC)
Sobretemperatura (PTC)
Sonda PTC cortocircuito/circuito
PTC Failure
abierto
Unbalance/Phase Loss
Desequilibrio/perdida de fase
Phase Sequence
Inversion de fases
Flashing
DIRECT CONNECTION
AUX VOLTAGE
SUPPLY
TRIP
L
K1
11
+
L1
PGR-6150
ALARM
K2
21
Alimentation
Digital input
Transformateur toroidal
PTC
Contact de déclench. NO-NC
Contact d'alarme NO-NC
RS-485 Modbus RTU
Bouton de réarmement
Connecteur RJ45
LEDs déclenchement/Alarme
Relais OK
Overload/Jam/Blocage
Temps démarrage excessif
Sous-intensité
Ground fault/différentiel
Transformateur toroidal alarme
Surchauffe (PTC)
Court circuit/circuit ouvert PTC
Déséquilibre/perte de phase
Phases sequence
5
GF CT
6
START
STOP
14
C
12
-
L2
N
7
PTC
8
24
22
C
N
C
-1-

Publicidad

loading

Resumen de contenidos para Littelfuse POWR-GARD PGR-6150 Serie

  • Página 1 Desequilibrio/perdida de fase Déséquilibre/perte de phase Phase Sequence Inversion de fases Phases sequence Flashing DIRECT CONNECTION AUX VOLTAGE GF CT SUPPLY TRIP START STOP PGR-6150 ALARM PGR-6150 SERIES • Country of origin: Spain • SEPTEMBER 17, 2010 • 1-800-TEC-FUSE (1-800-832-3873) • www.littelfuse.com...
  • Página 2 100 mètres (328’), ou lorsque l’influence des tensions transitoires à haute fréquence est prévue, il est conseillé d’utiliser du câble blindé et de connecter la maille du blindage à Terre. PGR-6150 SERIES • Country of origin: Spain • SEPTEMBER 17, 2010 • 1-800-TEC-FUSE (1-800-832-3873) • www.littelfuse.com...
  • Página 3 Motor Trip Class Motor Trip Class (s at 7x ) I (s at 7x ) I [Settings/General/Overload] *See Settings Table for a complete list. PGR-6150 SERIES • Country of origin: Spain • SEPTEMBER 17, 2010 • 1-800-TEC-FUSE (1-800-832-3873) • www.littelfuse.com...
  • Página 4 T R I P C L A S S Confirm setting T R I P C L A S S TRIP CLASS Settings changed PGR-6150 SERIES • Country of origin: Spain • SEPTEMBER 17, 2010 • 1-800-TEC-FUSE (1-800-832-3873) • www.littelfuse.com...
  • Página 5 Le relais PGR-6150 a un port R 485 pour communiquer avec un ordinateur ou d’un système SCADA sur une base continue. Le protocole utilisé est Modbus RTU (19,200 -8 bit - sans parité - 1 bit d’arrêt). Voir le manuel www.littelfuse.com.
  • Página 6: Caracteristicas Tecnicas

    SETTINGS CARACTERISTICAS TECNICAS CARACTERISTIQUE TECHNIQUES Min. Max. Step Unit Default General General Generales Générales Nominal Current Intensidad nominal Intensité nominal 0.01 CT Turns Ratio Relación CT Relation TI 2,000 (2*) (2*) (2*) Frequency Frecuencia Fréquence 50 Hz/60 Hz/Variable 50 Hz Motor Start Limit Umbral arranque motor Limite démarrage moteur...