Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

DECORATIVE VENTILATION
FAN WITH LIGHT
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufac-
turer. If you have questions, contact the manufacturer at
the address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the
service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the
service panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhaust-
ing of gases through the flue (chimney) of fuel burning
equipment to prevent backdrafting. Follow the heating
equipment manufacturer's guideline and safety standards
such as those published by the National Fire Protection
Association (NFPA), and the American Society for Heating,
Refrigeration and Air Conditioning Engineers (ASHRAE),
and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Do not install in a tub or shower enclosure.
8. Not for use in kitchens.
9. This unit must be grounded.
10. This unit is U.L. listed. Type I.C. inherently protected.
!
CAUTION
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2. This product is designed for installation in FLAT CEILINGS
ONLY. Do not mount this product in a wall.
3. The light fixture assembly must be mounted to the fan hous-
ing assembly included with this product. Do not mount the
light fixture assembly to a wiring outlet box.
4. To avoid motor bearing damage and noisy and/or unbal-
anced impellers, keep drywall spray, construction dust, etc.
off power unit.
5. Please read specification label on product for further infor-
mation and requirements.
Installer: Leave this manual with the
homeowner.
Homeowner: Use and Care
information on page 4.
TYPICAL INSTALLATIONS
CEILING
JOIST
HOUSING
HOUSING
CEILING
MATERIAL
LIGHT SHADE
HOUSING MOUNTED
DIRECTLY TO JOIST
2x6 (or larger)
Discharge parallel to joists.
"
"
I
JOIST
GLASS LIGHT SHADE
HOUSING MOUNTED TO "I" JOIST
Requires additional framing
*
Additional framing must be a 2x6 (minimum height), at least 9-inches long.
PLAN THE INSTALLATION
INSULATION
(Place around and
over fan housing.)
FAN
HOUSING
POWER
CABLE*
Seal gaps
around
housing.
4-IN. ROUND
DUCT*
Seal duct
joints with
*Purchase
tape.
separately.
MODEL 788CHNT
2 x 4
CEILING
JOIST or
TRUSS
GRILLE
CEILING
PAN
MATERIAL
GLASS
HOUSING MOUNTED
TO 2x4 TRUSS
Discharge parallel to joists.
ADDITIONAL
FRAMING
HOUSING
HOUSING
"
I
CEILING
JOIST
MATERIAL
GRILLE
PAN
for mounting.
Discharge parallel to joists.
OR
4-IN. ROUND
ELBOWS*
Page 1
2 x 4
CEILING
JOIST or
TRUSS
HOUSING
HOUSING
GRILLE
PAN
GLASS
LIGHT SHADE
*
"
ROOF CAP*
(with built-in
damper)
Keep duct
runs short.
WALL CAP*
(with built-in
damper)

Publicidad

Tabla de contenido
loading

Resumen de contenidos para NuTone 788CHNT

  • Página 1 MODEL 788CHNT Page 1 DECORATIVE VENTILATION FAN WITH LIGHT READ AND SAVE THESE INSTRUCTIONS TYPICAL INSTALLATIONS WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 2 x 4 2 x 4 1. Use this unit only in the manner intended by the manufac-...
  • Página 2 MODEL 788CHNT Page 2 INSTALL THE HOUSING PREPARE THE HOUSING New Construction 1. Choose the location for your fan/light in the ceiling. For best possible performance, use the shortest possible duct run and a minimum number of elbows. 1. Unplug blower and remove (3) screws securing blower assembly to housing.
  • Página 3: Connect The Wiring

    MODEL 788CHNT Page 3 SEAL BETWEEN CEILING FINISH THE INSTALLATION 4. Place housing in MATERIAL & HOUSING opening so that its bottom edge is flush with finished ceiling. Screw housing to joist through holes in housing as shown. 5. Seal between...
  • Página 4: Service Parts

    Broan-NuTone LLC, 926 West State Street, Hartford, WI 53027 (1-800-637-1453) If you must send the Fan or part to NuTone, as instructed by NuTone, you must properly pack the Fan or part—NuTone is not responsible for damage in transit.
  • Página 5: Ventilador Decorativo Con Lámpara

    MODELO 788CHNT Página 5 VENTILADOR DECORATIVO CON LÁMPARA LEA Y CONSERVE ESTAS INSTRUCCIONES INSTALACIONES TÍPICAS ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIOS, DESCARGAS ELÉCTRICAS O LESIONES PERSONALES, OBSERVE LAS VIGUETA SIGUIENTES PRECAUCIONES: 2 x 4 VIGUETA 2 x 4 CEILING...
  • Página 6: Preparación De La Cubierta

    MODELO 788CHNT Página 6 INSTALACIÓN DE LA CUBIERTA PREPARACIÓN DE LA CUBIERTA Nueva construcción 1. Seleccione la ubicación del ventilador con lámpara en el techo. Para obtener el mejor desempeño posible, utilice el tramo de conducto lo más corto posible y el menor número de codos.
  • Página 7: Conecte El Cableado

    MODELO 788CHNT Página 7 FINALIZACIÓN DE LA INSTALACIÓN APLIQUE SELLADOR ENTRE EL 4. Coloque la cubierta en MATERIAL DEL TECHO Y LA CUBIERTA la abertura de manera que su borde inferior quede al ras del techo terminado. Atornille la cubierta en la vigueta a través de los orificios...
  • Página 8: Uso Y Cuidado

    Usted es responsable de todos los costos de retiro, Pida piezas de repuesto dando como referencia el N.º DE PIEZA, no el N.º DE reinstalación y envío, seguro u otros cargos de flete incurridos en el envío del ventilador o la pieza a NuTone. Esta CLAVE.

Tabla de contenido