WS2001NS Series Passive Infrared Vacancy Wall Switch Sensors
SPECIFICATIONS
1200 sq. ft coverage area (FIG.1)
•
Electrical Ratings:
•
120VAC – 1000W Incandescent, 8.3A
Ballast 277VAC – 6.5A Ballast
Adjustable Time Delay: 30 seconds to 30 minutes
•
Zero-Cross Switching Circuitry
•
c-UL-us Listed
•
Manual ON Mode, Multi-Way function
•
This equipment has been tested and found to comply with
•
the limits for a Class B digital device pursuant to Part 15
of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a
residential installation.
PRECAUTIONS
CAUTION: RISK OF ELECTRICAL SHOCK. Turn power
OFF at service panel before beginning installation. Never
wire energized electrical components.
CAUTION: USE COPPER CONDUCTOR ONLY.
NOTICE: For indoor use only.
NOTICE: For installation by a licensed electrician in
accordance with National and/or local Electrical Codes and the
following instructions.
NOTICE: Confirm that device ratings are suitable for
application prior to installation. Do not install if any damage to
product is noticed.
INSTALLATION
1. Turn power OFF at the service panel.
2. (For new installation) Select a suitable location for the
sensor. Make sure the sensor will not be blocked by doors
or other obstacles. In addition, make sure the sensor will not
detect motion in adjacent areas or hallways causing the
lights to turn on when not desired. The sensor should have
a line of sight view of the occupant's hands for best
performance. Note the area of coverage diagram. Mount the
sensor 42" to 54" (107-137 cm) from the floor. (For existing
switch installation, remove old switch and replace with
sensor.)
3.
Wire the sensor(s) as below:
Single pole application (FIG 2):
Connect BLACK wire to HOT or LINE conductor from power
source.
Connect RED wire to lighting LOAD conductor.
Connect GREEN wire to equipment grounding conductor,
"GND". (Green, Green/Yellow or Bare wire) Ground wire
power sensors must be securely connected to ground to
operate properly.
Wiring Device-Kellems
40 Waterview Drive
Shelton, CT 06484
(800) 288-6000
www.hubbell-wiring.com
PD2894
Page 1
Hubbell Energy Efficiency Solutions
Installation and Operating Instructions
05/19
Top View /
Vue en plan / Vista por encima
Major Motion /
Mouvement fréquent / Movimiento frecuente
Minor Motion / Mouvement occasionnel / Movimiento ocasional
Side View /
Vue de côté / Vista lateral
Floor / Plancher
/ Piso
0' [m]
20' [6,1 m]
FIG. 2
YELLOW / JAUNE
/ AMARILLO
RED / ROUGE
GREEN / VERT
BLACK / NOIR
Wall box
/ NEGRO
Boîte murale
Caja de pared
Single Wiring /
Câblage un mode /
12' [3,7 m]
16' [4,9 m]
40' [12,2 m]
To lighting load
Vers la charge d'éclairage
Para iluminar la carga
/ ROJO
GROUND
MALT / TIERRA
/ VERDE
From power source
De la source d'alimentation
Desde la fuente de alimentación
Cableado un modo
English
FIG. 1
NEUTRAL
NEUTRE
NEUTRO