Descargar Imprimir esta página

Marineland H.O.T. MAGNUM 350 BIO-Pro Guía De Instalación Rápida

Publicidad

Enlaces rápidos

S S t t a a r r t t H H e e r r e e - -
1
Parts Check
2
1
3
4
5
6
Air Ejector
Cleaning
9
Wand
4
10
11
15
14
12
13
Squeeze to
open Impeller
Module
Lubricant
16
2
3
b
Canister Prep
For Periodic Water Polishing
or Gravel Washing. . .
Gaskets
Gaskets
Switch out Carbon Media
Leveling
Container with Micron Cartridge
and Rigid Core.
Micron Cartridge
Outside
Rigid Core
Inside
Additional Quick Setup Guide for
MAGNUM 350 BIO-Pro System
6
Parts Check
H.O.T. MAGNUM BIO-Wheel Pro System
O-Rings
Barbed Elbow Connector
w/ O-Rings
Outlet Adapter
Split Flow Diffuser
Connector Assy.
(Factory Assembled)
Cover
Spray Bar
O-Rings
Connector
Spray
Clips
Bar
BIO-Wheel
Assembly
Connector
Clips
Filter
Housing
BIO-Wheel
Sliding Nut
Bearings
and Screw (L-R)
Shut down system and remove Canister. Carry to sink. Remove Cover.
TO CHANGE FILTER MEDIA...
Change Media. Secure Cover. Return Canister. Restart Filter.
H.O.T. MAGNUM & H.O.T. MAGNUM With BIO-Pro System
1) Intake Tube, Strainer & O-Ring
2) Outlet Tube, Split Flow Diffuser
& O-Ring
3) Cover, D-Ring Seal &
Connector Clips - 2
4) Exhaust Gasket - 2
5) Internal Flow Diffuser
7
6) Center Exhaust Tube
7) Carbon Media Container & Lid
8) Rite Size "U" Foam Sleeve
9) Micron Cartridge & Core
Cleaning
10) Bottom Plate
8
Brush
11) Impeller Module
12) Impeller Assembly
13) Motor, Canister Collar &
Canister Assembly
14) Spring Latch
15) Hanger
16) Leveling Clip
Silicone
4
Placement
DO NOT PLUG IN.
Install Leveling Clip in slots
A.
at the bottom of Canister.
NOTE:
tube "elbow" at all times.
Hanger
Canister
Connector
Clip
Elbow
Clip
Split Flow
Diffuser Diverter
DO NOT PLUG IN.
B.
Hang Canister in desired position on the
OUTSIDE of aquarium. Adjust Hanger to fit
aquarium frame.
C.
Adjust Leveling Clip.
ONLY • Additional Quick Setup Guide for
7
Connector
Clip
NOTE:
Remove
Paper insert from
Snapper
each BIO-Wheel
Clamps
Hose
Snapper
Clamps
Barbed Elbow
Adapter
NOTE:
Do not over tighten
Thread the screws through the sliding
B.
nuts on the Filter Housing. (Left and right
nuts are marked. If nuts have slipped off
the housing, reinstall.) Tighten screws so
Filter Housing will not slip.
2
a
A1
A2
A.
Canister
1.
Lift Cover Lock to Open Canister.
2.
Swing Spring Latch downward
and remove Cover.
3.
Remove Internal Flow Diffuser
and Center Exhaust Tube.
4.
Remove Carbon Media
Container.
Assembly
Intake/Outlet
A.
Install Intake and Outlet Tubes. Wet O-Rings on tube ends with aquarium
water. Snap into place by pushing into proper port until Connector Clip
engages and locks. Intake is marked "IN", Outlet "OUT".
NOTE:
If assembling H.O.T. Magnum
with the (BIO-Pro System), Install
Keep water level above
Outlet Adapter BW Pro Tube.
Outlet Adapter BW Pro
"OUT"
"IN"
Connector
NOTE:
Keep water level above
Clip
tube "elbow" at all times.
NOTE:
To remove Tubes Push (don't squeeze),
Connector Clip downward. DO NOT remove
clip. Slide Intake or Outlet Tubes out of opening
then release Clip.
Intake Tube
NOTE:
Strainer
Hi-Lo Flow
MAGNUM 350 BIO-Pro System
Mount & Placement of Filter Housings
A.
Check BIO-Wheel Assembly for proper installation. BIO-Wheel should rotate
Spray
freely. Also check that the Spray Bar is snapped in place with Connector Clip.
Bar
Connector
Clip
Filter Housing Cover
NOTE:
To remove Spray Bar for cleaning, push
Connector Clip downward (Don't Squeeze).
Mount the Filter Housing on the
C.
back wall of aquarium, next to H.O.T.
Magnum canister on Outlet Tube side.
Replace Filter Housing Cover.
D.
Snap-Lock Barbed Elbow Connector with
O-Rings into BIO-Wheel Pro and slide Barbed
Elbow Adapter into Outlet Adapter.
Questions or Missing Parts?
Call Customer Service at:
Quick Setup Guide
Canister Prep
A2
Remove
Cover & Gasket
B1
A3
Remove
Internal Flow
Diffuser
Remove
Center
B2
Exhaust Tub
& Gasket
A4
Remove
B3
Carbon
Replace
Media
Rite-Size
Container
Filter Sleeve
B.
Carbon Media Container
1.
Remove Cover and Fill with Black Diamond Carbon.
2.
Replace Cover and rinse thoroughly.
3.
Slide Rite-Size Filter Sleeve over Container.
4.
Replace Container over Impeller Module and Bottom Plate.
5.
Replace Exhaust Gasket around Center Exhaust Tube.
6.
Replace Internal Flow Diffuser.
5
Elbow
CAUTION:
To avoid water spills and
leaks, make sure all connections are
secured where indicated.
NOTE:
A slight rattling noise is normal
Adjust Split Flow Diffuser Diverter.
ONLY DURING STARTUP. If noise persists,
shut off filter and check for dirt or debris
that may be in bottom of Canister.
Side-to-Side Flow
ONLY • Additional Quick Setup Guide for
Barbed Elbow Connector
w/ O-Rings
Connector Assy.
(Factory Assembled)
Barbed Elbow
Adapter
Outlet
Adapter
(800) 322-1266
C3 Wet Cover
D-Ring & Replace
C1
C2
B6
Internal
Flow
Diffuser
B5
Gaskets
C4
Center
Cover Lock
Exhaust Tube
Groove
Spring Latch
B4
C.
Fill and Seal Canister
1.
Add water until Internal Flow Diffuser is covered.
2.
Install Exhaust Gasket onto Cover.
Wet D-Ring with
.
3.
Aquarium Water
Replace Canister Cover. Raise Cover Lock to
4.
engage Spring Latch. Snap Spring Latch in to
groove. Push Cover Lock down to close and
seal canister.
Start Up
STOP:
If assembling H.O.T. Magnum with (BIO-Pro
System),
DO NOT PLUG IN.
Continue on to STEP #6
for ADDITIONAL connection directives.
Plug in power cord. Be sure
to create a "Drip Loop". Press
On/Off switch to start filter.
On/Off Switch
NOTE:
Drip Loop
(for safety)
MAGNUM 350 BIO-Pro System
ONLY
8
Start Up
Plug in power cord. Be sure
A.
to create a "Drip Loop". Press
on/off switch to start filter.
On/Off Switch
Spray Bar
Adjust BIO-Wheel Spray Bar for
B.
consistent rotation of BIO-Wheel.
CAUTION:
To avoid water spills and
leaks, make sure all connections are
secured where indicated.
NOTE:
A slight rattling noise is normal
ONLY DURING STARTUP. If noise persists,
shut off filter and check for dirt or debris
that may be in bottom of Canister.
NOTE:
Drip Loop
(for safety)
05/07 11957
www.marineland.com

Publicidad

loading

Resumen de contenidos para Marineland H.O.T. MAGNUM 350 BIO-Pro

  • Página 1 Screw (L-R) (for safety) 05/07 11957 Shut down system and remove Canister. Carry to sink. Remove Cover. TO CHANGE FILTER MEDIA... Questions or Missing Parts? (800) 322-1266 Change Media. Secure Cover. Return Canister. Restart Filter. Call Customer Service at: www.marineland.com...
  • Página 2 Sistema H.O.T. MAGNUM & H.O.T. MAGNUM con BIO-Pro Guía de instalación rápida Guide d’installation rapide des systèmes H.O.T. MAGNUM et H.O.T. MAGNUM avec BIO-Pro C C o o m m i i e e n n c c e e a a q q u u í í - - C C o o m m m m e e n n c c e e r r i i c c i i –...

Este manual también es adecuado para:

H.o.t. magnumH.o.t. magnum with bio-pro