1. 50%. When the room temperature is higher than 77°F/25°C, the target humidity is held to 45%.
NOTE: While in this mode, humidity levels cannot be set using the Up/Down pads.
2. FILTER Pad: The check filter feature is a reminder to clean the Air Filter for more efficient
operation. The Filter light (Clean Filter indicator light) will illuminate after 250 hours of operation.
To reset after cleaning the filter, press the Filter pad and the light will go off.
3. TURBO Pad: Controls the fan speed. Press to select either High or Normal fan speed. Set the fan
control to High for maximum moisture removal. When the humidity has been reduced and quiet
operation is preferred, set the fan control to Normal.
4. ION Pad (optional): Press to activate the ionizer. Anions are automatically generated by ionization.
The anions deactivate the airborne chemical vapors and dust particles. Press it again to stop the
function.
5. POWER Pad: Press to turn the dehumidifier on and off.
6. (<)/(>) Down/Up Pads:
7. (<)/(>) Down/Up Pads:
• Humidity Set Control Pads: The humidity level can be set within a range of 35% RH (Relative
Humidity) to 85% RH in 5% increments. For drier air, press the (<) pad and set to a lower percent
value (%). For damper air, press the (>) pad and set a higher percent value.
• TIMER Set Control Pads: Use the Up/Down pads to set the Auto start and Auto stop time from
0.0 to 24.
8. TIMER Pad: Press to initiate the Auto start and Auto stop feature, in conjunction with the (>) and
(<) pads.
9. CONTINUE Pad: Press to activate the continuous dehumidifying operation.
10. DISPLAY: Shows the set % humidity level from 35% to 85% or Auto start/stop time (0‒24) while
setting, then shows the actual room humidity level percentage (within 5% accuracy) in a range of
30% to 90% RH.
Error Codes and Protection Code:
AS - Humidity sensor error. Unplug the unit and plug it back in. If error repeats, call for service.
ES - Temperature sensor error. Unplug the unit and plug it back in. If error repeats, call for service.
P2 - Bucket is full. Bucket is full or bucket is not in right position.-Empty the bucket and replace it in
the right position.
E3 - Unit malfunction. Unplug the unit and plug it back in. If error repeats, call for service.

OTHER FEATURES

Bucket Full Light
Glows when the bucket is ready to be emptied.
Auto Shut Off
The dehumidifier shuts off when the bucket is full, or when the bucket is removed or not replaced in
the proper position. When the setting humidity is reached, the unit will be shut off automatically. For
some models, the fan motor will continue operating.
Auto Defrost
When frost builds up on the evaporator coils, the compressor will cycle off and the fan will continue to
run until the frost disappears.