3 Minute Pause
After the unit has stopped, it can not be restarted until 3 minutes have elapsed. This is to protect the
unit. Operation will automatically resume after 3 minutes.
Check Filter Feature
The system starts to count the hours of operation once the fan motor is used the first time. The check
filter feature is activated when the accumulated operation time reaches 250 hours or more. At that
point, the Reset light (Clean Filter indicator light) will flash at one time per second to alert the user
that the filter needs cleaning. After cleaning the air filter, press the Filter pad and the Reset light (Clean
Filter indicator light) will turn off.
Auto-Restart
If the unit is turned off unexpectedly due to a power cut, it will restart with the previous function
settings automatically retained when the power resumes.
Setting the Timer
• When the unit is on, press the TIMER Pad and the TIMER Off indicator light illuminates. It
indicates that the Auto Stop program is initiated. Press TIMER again and the TIMER On indicator
light illuminates. It indicates that the Auto Start is initiated.
• When the unit is off, first press the TIMER button, and the TIMER On indicator light illuminates.
It indicates the Auto Start program is initiated. Press it again the TIMER Off indicator light
illuminates. It indicates the Auto Stop is initiated.
• Press or hold the UP or DOWN pad to change the Auto time by 0.5 hour increments, up to 10
hours, then at 1 hour increments up to 24 hours. The control will count down the time remaining
until start.
• The selected time will register in 5 seconds and the system will automatically revert back to
displaying the previous humidity setting.
• When the Auto Start & Auto Stop times are set within the same program sequence, the Timer On
and Timer Off indicator lights both illuminate, identifying that both ON and OFF times are now
programmed.
• Turning the unit ON or OFF at any time or adjusting the timer setting to 0.0 will cancel the Auto
Start/Stop function.
• When LED display window displays the code of P2, the Auto Start/Stop function will also be
cancelled.
REMOVING THE COLLECTED WATER
There are two ways to remove collected water.
1. Use the bucket
• When the unit is off, if the bucket is full, the Full indicator light will light.
• When the unit is on, if the bucket is full, the compressor and the fan will turn off, the Full
indicator light will light, and the digital display will show P2.
• Slowly pull out the bucket. Grip the left and right handles securely, and carefully pull it out
straight so that water does not spill (see Fig. 1). Do not set the bucket on the floor because the
bottom of the bucket is not level/flat. The bucket will fall and cause the water to spill.
• Throw away the water and replace the bucket (see Fig. 2). The bucket must be in correctly and
securely seated for the dehumidifier to operate.
INSTRUCTIONS