PROBLEM
Unit does not start
Dehumidifier does not dry the
air as it should
The unit makes a loud noise
when operating
Frost appears on the coils
Water on floor
ES, AS, P2, EC, and E3 appear in
the display
The pump operation on light
blinks at 1 Hz
To prevent injury to the user or other people and property damage, the following instructions must
be followed. Incorrect operation due to ignoring of instructions may cause harm or damage.
The seriousness is classified by the following indications.
WARNING
CAUTION
Meaning of symbols used in this manual are as shown.
Do not use the unit in small
places.
• Lack of ventilation can cause
overheating and fire.
www.Hydrofarm.com
8
INSTRUCTIONS
TROUBLESHOOTING
CAUSES AND SUGGESTED REMEDIES
• Make sure the dehumidifier's plug is inserted completely into the outlet.
• Check the house fuse/circuit breaker box.
• Dehumidifier has reached its preset level or bucket is full.
• Water bucket is not in the proper position.
• Did not allow enough time to remove the moisture.
• Make sure there are no curtains, blinds or furniture blocking the front or
back of the dehumidifier.
• The humidity control may not be set low enough.
• Check that all doors, windows and other openings are securely closed.
• Room temperature is too low, i.e. below 50C (410F).
• There is a kerosene heater or something giving off water vapor in the room.
• The air filter is clogged.
• The unit is tilted instead of upright as it should be.
• The floor surface is not level.
• This is normal. The dehumidifier has an Auto defrost feature.
• Hose to connector or hose connection may be loose.
• Back drain plug might be removed or loose.
• These are error codes and protection code. See the CONTROL PADS section.
• Clean the filter of the pump.
• Check that the pump hose is not kinked or blocked.
• Empty the water from the bucket.
This section indicates the possibility of death or serious injury.
This section indicates the possibility of injury or damage to property.
Never do this.
Always do this.
Do not put in places where
water may splash on the unit.
• Water may enter the unit and
degrade the insulation. It may
cause an electric shock or fire.
Place the unit on a level,
sturdy section of the floor.
• If the unit falls over, it may
cause water to spill and damage
belongings, or cause electrical
shock or fire.