WAKE UP
Safely bypasses the discharge protection if active on the
battery.
STEP 1 ACCEPT
Tests if the battery can accept charge. This step prevents that
charging proceeds with a defect battery.
STEP 2 BULK
Charging with maximum current until approximately 90%
battery capacity.
STEP 3 ABSORPTION
Charging with declining current to maximize up to 95%
battery capacity.
STEP 4 ANALYZE
Tests if the battery can hold charge. Batteries that can not hold
charge may need to be replaced.
STEP 5 COMPLETION
Final charge with increased voltage.
STEP 6 MAXIMIZATION
Final charge with maximum voltage up to 100% battery
capacity.
STEP 7 PULSE
Maintaining the battery at 95–100% capacity. The charger
monitors the battery voltage and gives a pulse when
necessary to keep the battery fully charged.
EN • 13