POWER LAMP
If the power lamp is lit with a:
1. STEADY LIGHT
The mains cable is connected to the wall
socket.
2. FLASHING LIGHT:
The charger has entered the energy save
mode. This happens if the charger isn´t con-
nected to the battery within 2 minutes or the
battery on board UVP (under voltage protec-
tion) is activated.
READY TO USE
The table shows the estimated time for an empty
battery to reach 90% state of charge (SOC).
Please note that charging times are
longer in low ambient temperatures.
BATTERY SIZE (AH)
40Ah
60Ah
100Ah
10 • EN
TIME TO 90% CHARGED
6h
9h
15h
ERROR LAMP
If the error lamp is lit, check the following:
1. Is the chargers positive lead connected
to the battery's positive pole?
2. Is the charger connected to a 12V
Lithium Ion battery?
3. Are the terminals short circuited?
4. Has charging been interrupted in
or
?
Restart the charger by pressing/holding the
RESET button. If charging is still being inter-
rupted, the battery...
...can not accept charge.
...may be too large for the charger to wake
up. Press/hold RESET button for 10 seconds
up to 5 times.
...a parallel load may be connected to the
battery. Disconnect the battery and try
again.
...can not keep charge and may need to be
replaced.