Pump set (Rotor/ Stator) - Assembly/Disassembly

4.

Maintenance and repair

4.1
Pump set (Rotor/ Stator) - Assembly/Disassembly

4.1.1 Preperation

Personal protective equipment:
- Safety goggles
- Security shoes (steel toed)
- Hearing Protection
- Gloves
Tools:
- Combination wrench for M8, M12 (1/4"), M16 (3/8")
- Slotted screwdriver 6,5mm x150mm (2x)
- Disruptive discharge ø10mm
- Hammer 250g
- crane
- Round sling (2x)

4.1.2 Assembly/ Disassembly

1. Before starting work, Ensure the absence of voltge and secure it against
inadvertent reconnection.
DANGER!
Danger of beeing pulled in by accidental restarting the pump.
Death or serious bodily injury.
• Remove the connection for the power supply
• Lock the main switch
2. Remove (2022) protective guard.