OPERATING INSTRUCTIONS
gas valve-hose connection (Figure 10)
CHECKING FOR LEAKS
To perform a leak test:
1.Make 2-3 oz. of leak solution by mixing one part liquid dishwashing detergent and three parts
water. Noted: make sure control knob is "OFF".
2.Apply several drops of solution where the cylinder attaches to regulator (see Figure 8), inspect
the solution at the connection looking for bubbles. If NO bubbles appear, the connection is
secure. If bubbles appear, the connection has the leak, disconnect the regulator, reconnect,
perform another leak check. If you continue to see bubbles after several attempts, cylinder
valve is defective and should be returned to cylinder's supplier.
3.Apply several drops of solution where gas valve attaches to bellows (see Figure 9), where gas
valve attaches to hose (see Figure 10), and where inlet tube attaches to bellows (see Figure
11). If NO bubbles appear, the connections are secure. If bubbles appear, the connection has
the leak, disconnect, reconnect, perform another leak check. If you continue to see bubbles
after several attempts, the part is defective and should replace the part.
LIGHTING INSTRUCTIONS
1.Push in the gas control knob slightly and turn to "OFF".
2.Turn the gas control knob to "ON/MIN".
3.Push in the gas control knob all the way in and hold. Continue to press the ignition button for 15
seconds.
4.If the burner does not light in 15 seconds, release the knob and it will pop back out. Wait 5
minutes before attempting to light the burner again, repeat above step 1 to 3.
TO TURN OFF GAS
1.Push in the gas control knob slightly and turn to "OFF".
WARNING:
1.For your safety, read and follow the Lighting Instructions in this manual and on the Rating Plate
on the appliance.
2.IMPROPER LIGHTING PROCEDURES COULD RESULT IN A FIRE HAZARD OR EXPLOSION
HAZARD OR PROPERTY DAMAGE, INJURY OR LOSS OF LIFE.
LIGHTING INSTRUCTIONS
1. Push in gas control knob slightly and
turn to "OFF".
2. Turn gas control knob to "ON/MIN".
3. Push in gas control knob all the way
and hold. Continue to press the
ignition button for 15 seconds.
4. If the burner does not light in 15
seconds, release the knob and it will
ON/MIN
pop back out. Wait 5 minutes before attempting
(ENC./MÍN.)
to light the burner again, repeat step 1 to 3.
TO TURN OFF GAS
1. Push in gas control knob slightly and turn to "OFF".
INSTRUCCIONES DE ENCENDIDO
1. Presione ligeramente la perilla de control del gas y gírela a la
posición "APG" (apagado).
2. Gire la perilla de control del gas a "ENC/MÍN" (encendido/mínimo).
3. Presione la perilla de control del gas hasta el fondo y mantenga presionada.
Siga presionando el botón de encendido durante 15 segundos.
4. Si el quemador no se enciende en 15 segundos, suelte la perilla y esta
volverá a su posición hacia afuera. Espere 5 minutos antes de intentar
encender el quemador nuevamente, repita los pasos 1 al 3.
PARA CERRAR EL GAS
1.
Presione ligeramente la perilla de control del gas y gírela a
la posición "APG" (apagado)
8
inlet tube-bellows connection (Figure 11)
OFF ( A P G. )
gas control knob
ignition button
M A X
( M Á X . )
1 AAA
IGNITOR
1.5V
( Encendedor )
Figure 12