Optex BX SHIELD Serie Instrucciones De Instalación página 5

Tabla de contenido

Publicidad

4-2. Switch setting
Réglages des interrupteur
FR
Impostazioni degli interruttori
IT
Ajuste da chave
PT
FR
BXS-R
1
2
3
BXS-RAM
1
2
3
Type de
* Sorties
Article
LED
alarme et
individuelles
probléme
ON
ON
N.O.
ON
OFF
OFF
N.C.
OFF
IT
BXS-R
1
2
3
BXS-RAM
1
2
3
Tipo di
* Uscite
Articolo
LED
allarme e
individuali
guasto
N.A.
ON
ON
ON
[norm. aperto]
N.C.
OFF
OFF
OFF
[norm. chiuso]
PT
BXS-R
1
2
3
BXS-RAM
1
2
3
Tipo de
* Saídas
alarme e
Item
LED
individuais
problema
N.A.
ON
ON
ON
[norm. aberto]
N.F.
OFF
OFF
OFF
[norm. fechado]
Factory default
Défaut
FR
Werkseinstellung
DE
IT
Defecto
ES
PT
Fabrieksinstellingen
NL
4-3. PIR sensitivity
Sensibilité PIR
FR
DE
Sensibilità PIR
IT
ES
Sensibilidade do PIR
PT
NL
EN
High
Middle
(Default)
Low
FR
DE
Haute
Hoch
Moyen
Mittel
(Défaut)
(Werkseinstellung)
Faible
Niedrig
IT
ES
Alta
Alta
Media
Media
(Defecto)
Bassa
Baja
Schaltereinstellungen
DE
Ajuste del conmutador
ES
Instellingen switches
NL
4
5
6
4
5
6
7
Minuterie
**
PIR Extrême Haute
d'economie
Anti-
des
masquage
Gauche
Droite
batteries
ON
ON
5 sec.
ON
OFF
OFF
120 sec.
OFF
4
5
6
4
5
6
7
** PIR Estrema Alta Tempo
Anti-
risparmio
maschera
Sinistra
Destra
batteria
mento
ON
ON
5 sec.
ON
OFF
OFF
120 sec.
OFF
4
5
6
4
5
6
7
** PIR Extrema Alto Timer de
economia
Antimascar
de carga
amento
Esquerda
Direito
da bateria
ON
ON
5 sec.
ON
OFF
OFF
120 sec.
OFF
Sensibilidad PIR
PIR gevoeligheid
Left side
Right side
PT
NL
Alta
Média
(Fabrieksinstellingen)
Baixa
EN
BXS-R
1
2
BXS-RAM
1
2
*
Alarm &
Individual
Item
LED
Trouble type
outputs
ON
ON
N.O.
OFF
OFF
N.C.
DE
BXS-R
1
8
BXS-RAM
1
Alarm und
Usage
Artikel
LED
störung
futur
ON
ON
OFF
OFF
N/A
ES
BXS-R
1
8
BXS-RAM
1
Tipo de
Utilizzo
Ítem
LED
alarma y
futuro
problema
ON
ON
OFF
OFF
N/A
NL
BXS-R
1
8
BXS-RAM
1
Alarm en
Uso
Item
LED
problemen
futuro
ON
ON
OFF
OFF
N/A
*Alarm outputs
** PIR Extreme High
; ON/OFF by DIP SW No.4 & 5
DIP switch No.4
(Left side)
Hoog
Middelmatig
+ Make sure to perform a walk test
after sensitivity adjustment.
Laag
3
4
5
6
3
4
5
6
** PIR Extreme High
Battery
saving timer
Left
Right
ON
ON
ON
5 sec.
OFF
OFF
OFF
120 sec.
2
3
4
5
2
3
4
5
**
PIR Extrem Hoch
* Einzelne
Ausgänge
Links
Recht
typ
N.O.
ON
ON
ON
N.C.
OFF
OFF
OFF
2
3
4
5
2
3
4
5
** PIR Extrema Alto Temporizador
* Salidas
individuales
Izquierda Derecha
N.O.
ON
ON
ON
N.C.
OFF
OFF
OFF
2
3
4
5
2
3
4
5
**
*
PIR Extreem Hoog
Individuele
uitgangen
Links
Rechts
type
N.O.
ON
ON
ON
N.C.
OFF
OFF
OFF
; Individual outputs ON/OFF by DIP SW No.3
Sensitivity
DIP switch No.5
(Right side)
Extreme High
M
7
8
Anti-
Future use
masking
ON
N/A
OFF
6
6
7
8
Batterie
Anti-
Zukünftiger
Energiespar-
maskierung
Gebrauch
Timer
5 sec.
ON
N/A
120 sec.
OFF
6
6
7
8
Antienmas
Uso
de ahorro
caramiento
futuro
de batería
5 sec.
ON
N/A
120 sec.
OFF
6
6
7
8
Batterij
Anti
Toekomstig
besparing
maskering
gebruik
timer
5 sec.
ON
N/A
120 sec.
OFF
Temperature
difference
H
Small
M
L
H
Factory default
Factory default
L
Large
5

Publicidad