INSTRUCTION ON MOUNTING AND USE
Check also the drawings on the initial pages with the alphabetical
and numerical references in the explanatory text.
Closely follow the instructions in this manual. We cannot
accept liability for any faults, detriment or fire damage to the
appliance due to non-compliance with the manual's
instructions. Installation and electrical connections must be
executed by a qualified technician. You should affix the hood
to a wall of sufficient weight-bearing capacity, so not to one
made of plasterboard. Do not install it inside a cupboard.
Attach it to the wall using the anchors provided: Fig. 3 diameter
12, Fig. 5 diameter 8.
Installation
The cooker hood must be placed at a minimum distance of 65
cm from the cooking plane for electric cookers and 75cm for
gas or mixed cookers.
If the instructions for installation for the gas hob specify a greater
distance, this has to be taken into account.
Do not tile, grout or silicone this appliance to the wall. Surface
mounting only. Do not fix chimney flue to furniture or fly over
shelves unless the chimney flue can be easily removed, in
case maintenance is ever required.
Use
The cooker hood is provided with an upper air exit B for
discharging fumes externally for models including chimney
flue C ( Suction Version A- exhaust pipe not supplied).
If cooking fumes and vapours cannot be externally discharged,
the cooker hood can be used in the recirculating version
F: the installation of 1 active charcoal filter F allows the
recirculation of fumes and vapours through the upper grid G.
Electrical connection
Make sure that there is a power socket near the hood and
that the system has a 30 mA differential. The mains voltage
must be the same as that on the label inside the hood. The
hood has a 1250 mm power cable with or without plug: if it
does have a plug, connect the hood to an accessible
approved socket; or if it does not (connection direct to the
mains), fit an approved bipolar switch with a minimum
contact opening of no less than 3 mm (accessible). This
installation and electrical connection must be executed by a
qualified technician.
Operation
12 3 4 5 6 7 8 9
General notes: the controls are touch sensitive and a light
pressure on the buttons is sufficient to activate any function.
Light ON/OFF button: when the button is touched
the hood lights turn on.
Motor ON/OFF button (9 speeds + air exchange):
when the button is touched the hood starts up in air exchange
m o d e .
1 2 3 4 5 6 7 8 9
Speed adjustment buttons You will be able to change the
desired extraction
speed (power) by touching buttons
„1,2,3,4,5,6,7,8 and 9". It can be regulated both by choosing
the desired speed and by gradually scrolling through the
s p e e d s .
PTC
Air exchange button when the button is touched
the air exchange mode starts up which allows continuous air
exchange thereby improving living area comfort. When this
mode is operational the winter function cannot be engaged.
Timer button: when this button is touched the timer
mode will start up, regardless of the selected extraction speed.
At the first touch, the timer will be set to run for 5 minutes (the
led will flash once), at the second touch 10 minutes (the led
will flash twice), and at the third touch 20 minutes (the led will
flash three times).
Winter button:
and, therefore, to maintain a constant living area temperature,
it is advised that this mode be used above all during particularly
hot or cold spells.
FILTER RESET
Saturated grease filter: every 40 hours of hood operation,
the motor button will flash in red indicating that the metal filters
need to be washed.
Saturated charcoal filters: every 120 hours of hood
operation, the motor button will flash in red indicating that the
charcoal filters need to be replaced.
Note: by keeping both the" timer „ and „ motor" buttons
depressed at the same time for several seconds, the saturated
filter indicator will be reset. Warning! This operation should
only be carried out after filter maintenance has been
c o m p l e t e d .
Operation
A
C
With the hood switched off, pressing any key will activate
the control panel in stand-by mode. The symbols are backlit
by a white light, allowing you view and select the desired
function.
Pressing one of the keys again will start the corresponding
function, and its symbol will light up. After all functions have
been switched off, the control panel will remain in stand-by
mode for around 30 seconds and then switch off automatically.
A: Light ON/OFF key: press this touch sensor to switch
on or off the lights of the hood.
C: Motor ON/OFF key (4 speed): press this touch sensor
to switch on the hood extractor fan at the same speed as it
was when last switched off. Use the „D" and „B" keys to
vary the speed (power) of extraction.
B: Decrease extraction speed (power) key: press this
touch sensor to reduce the extraction speed of the hood.
D: Increase extraction speed (power) key: press this
touch sensor to increase the extraction speed of the hood.
6
in order to reduce energy consumption
TSL2
B
D
E
F