THERMISTOR
238.23Ω @ 25 °C 77
GAS MODEL
Radiant Sensor(10RS)
Resistance value < 1 Ω
If resistance is infinite, replace Radiant sensor
Igniter(101D)
Resistance value 40~400 Ω
If resistance is infinite, replace Igniter
Technical_information-02835D-02_EN.indd 12
WARNING
Gas Valve(25M01A)
Valve 1-2 : Resistance value about 1365 Ω
Valve 1-3 : Resistance value about 560 Ω
Valve 4-5 : Resistance value about 1325 Ω
If resistance is infinity, replace Valve
Thermostat (60T21 Hi-Limit)230F-50F
Resistance value < 1 Ω
If resistance is infinity, replace Thermostat