RIB P1 Manual Del Usuario página 26

Ocultar thumbs Ver también para P1:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

G
B
EVENT
DIP 1 ON (hold-to-run mode)
Or failure of a safety device
DIP 2 ON (stroke programming)
Programming sequence stopped due to intervention of a safety
device
EVENT
No transmitter code entered
DIP 1 ON > DIP 2 ON - transmitter code programming for full
opening
DIP 1 ON > DIP 2 ON > DIP 3 ON - transmitter code programming for
R-AUX relay
Correct transmitter codes programming for opening and R-AUX
relay
Remote control code not present in memory
Memory saturated by remote control codes (1000 codes saved)
Radio code deletion for opening and R-AUX relay
EVENT
Stop button pressed
Photocell intervention
Edge intervention
Failure of a safety device or safety device engaged for too long
Alarm from edge
Failed photocells auto-test alarm
Functional block activated by smartphone
Achievement of set cycles
Energy saving activated by smartphone
Alarm - no limit switches reached or unlocked barrier
After having carried out the various connections and having supplied voltage, all the LEDS are
switched OFF.
The motor opens and closes, but it has no strength and moves slowly.
The gate opens but does not close after the time set.
The gate does not close by activating the various START, RADIO and CLOSE buttons.
By activating the START, OPEN or CLOSE button the barrier does not move.
The slowing phase is not performed.
TABLE SUMMARISING VISUAL AND SOUND ALARMS
SIGNALS DURING PROGRAMMING SEQUENCE
BUZZER STATUS
10 s tone with 2 s pause
BUZZER STATUS
WARNING SIGNALS DURING OPERATION
BUZZER STATUS
2 Tones every 5 s for 1 minute
(It is renewed by giving a command)
4 Tones every 5 s for 1 minute
(It is renewed by giving a command)
6 Tones every 5 s
(It is renewed by giving a command)
FAULT
FLASHER STATUS
OFF
OFF
OFF
OFF
OFF
FLASHER STATUS
OFF
OFF
OFF
OFF
OFF
OFF
1 Tone
OFF
OFF
OFF
OFF
OFF
2 Tones
OFF
FLASHER STATUS
OFF
OFF
1 Tone
OFF
2 Tones
OFF
OFF
OFF
Flashes for 1 minute
OFF
OFF
OFF
OFF
OFF
OFF
5 Tones
Flashes for 1 minute
On the board there are resettable fuses which intervene in the event of a short circuit,
interrupting the output assigned to them.
In the event of troubleshooting, it is advisable to disconnect all the removable connectors and
insert them one at a time in order to more easily identify the cause of the fault.
Check the integrity of fuse F1.
In case of interrupted fuse use only of adequate value
F1 = T 5A Fuse for motor protection
Check trimmers LOW SPEED OPEN and LOW SPEED CLOSE adjustment.
Make sure that the TCA trimmer is activated with LED DL11 ON.
B.I.O. contact always on / green led on => check the status of the clock connected to B.I.O.
input.
Photocells Auto-test failed => check the connections between the control panel and the
photocells.
Faulty safety edge contact. Faulty photocells contact => Fix or replace the faulty contact.
Photocells Auto-test failed => check the connections between the control panel and the
photocells.
START, OPEN or CLOSE command always active.
Check and replace any buttons or micro-switches of the selector switch.
Check LOW SPEED OPEN e LOW SPEED CLOSE trimmers adjustment.
26
DL1 LED STATUS
Flashes ON/OFF 250 ms
Flashes ON/OFF 500 ms
On steady
DL12 LED STATUS
Flashes red/green
Flashes red for 10 s
Flashes orange for 10 s
Turns green once
Turns red once
Runs 6 green flashes
Runs 2 green flashes
LED STATUS AND SIGNAL OUTPUT
Led DL6 turns OFF
Led DL7-8 turns OFF
Led DL9 turns OFF
Led DL1 flashes ON/OFF 250 ms
No led combined
No led combined
Led DL12 is steady on green.
No leds matched
Blue led flashes once every 5 s
No leds matched
SOLUTION

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ac08086Ac08087

Tabla de contenido