SERVICE AND ADJUSTMENTS
REPLACING BATTERY (See Fig. 51)
WARNING: Do not short battery ter mi-
nals by allowing a wrench or any other
object to contact both terminals at the
same time. Before connecting battery,
remove metal bracelets, wristwatch
bands, rings, etc. Positive terminal
must be connected first to prevent
sparking from ac ci den tal grounding.
Lift hood to raised position.
Remove terminal cover.
Disconnect BLACK battery cable then RED battery
cable and carefully remove battery from tractor.
Install new battery with terminals in same position as
old battery.
Reinstall terminal cover.
First connect RED battery cable to positive (+) battery
terminal with bolt and nut as shown. Tighten securely.
Connect BLACK grounding cable to negative (-) bat tery
terminal with remaining bolt and nut. Tighten securely
Close hood.
TERMINAL
COVER
POSITIVE
(RED)
CABLE
NEGATIVE
(BLACK)
CABLE
Fig. 51
TO REPLACE HEADLIGHT BULB
Raise hood.
Pull bulb holder out of the hole in the backside of the
grill.
Replace bulb in holder and push bulb holder securely
back into the hole in the backside of the grill.
Close hood.
INTERLOCKS AND RELAYS
Loose or damaged wiring may cause your tractor to run
poorly, stop running, or prevent it from starting.
Check wiring.
TO REPLACE FUSE (See Fig. 52)
Unit has two automotive type fuses. Replace primary
operation fuse with a 20 amp and the differential lock
actuator fuse with a 10 amp. The fuse holders are located
behind the dash.