INSTALLATION OF THE STOP LIMIT SWITCHES
1. Place the gate in the maximum closed position, and then
attach the limit switch screw as shown in the figure.
2. Place the gate in the maximum open position, and then
attach the limit switch nut as shown in the figure, and
tighten the screw.
EMERGENCY UNBLOCKING
In the case of a power failure, the gate can be unblocked
mechanically by operating the motor.
Insert the supplied unblocking lever and rotate 180° clockwise.
Automation will be automatically restored the first time the
motor is operated.
12