INITIAL CONFIGURATION
The apparatus must be configured before the first use following the below instructions:
I) Important! Before you start, make sure there is no pot on the hob
II) Disconnect the appliance from the grid by removing the fuse or turning the circuit breaker off
III) Reconnect the table to the grid
IV) Procedure:
* Take a pot with a ferromagnetic bottom with a minimum diameter of 16 cm
* start the procedure within 2 minutes after reconnecting the hob to the grid
* don't use the [ 0/I ] button
V) First step: cancel the existing configuration
1) Press and hold the n°2 button
2) The symbol [ . ] will appear on each display
3) With your other hand, press in succession and
quickly (less than 2s) each [ . ] display.
Begin from the front right side and turn counter
clockwise, as described in the picture (a -> b -> c -> d)).
A double "beep" means an error occurred. If so, start again from point 1).
4) Remove your fingers from the touch control, then push and hold button 1 for few
seconds, until the blinking [ E ] symbols appear.
5) Wait until [ E ] symbols stop blinking.
6) After few seconds, [ E ] will automatically become [ C ] confirming that the previous
configuration was cancelled.
Note: For induction hobs with 3 cooking zones, because the right front zone doesn't ex-
ist, begin the procedure with the right rear zone (b).
For induction hobs with 2 cooking zones, because the front zone doesn't exist, begin the
procedure from zone (a) to (b).
VI) Second step: new configuration
1) Take a pot with a ferromagnetic bottom with a minimum diameter of 16 cm.
2) Select a cooking zone by pushing on the corresponding [ C ] display
3) Place the pot on the area that needs to be configured
4) Wait until the [ C ] display becomes a [ - ]. The selected cooking zone is now
configured.
5) Follow the same procedure for each cooking zone with a [ C ] display.
6) All the cooking zones are configured once all the displays are turned off.
Note: Please use the same pot for the whole procedure.
Never put several pots together on the zones during the setup-process.
WHAT TO DO IN CASE OF A PROBLEM
The symbol [ E4] appears :
Reconfigure the table as above from step one
If the symbol remains, please contact our After sales service
d
14
c
b
a