ELECTRICAL CONNECTION

 The installation of this appliance and the connections of the electrical network should be
carried out by a specialised and qualified technician in respect with the local norms and
standards in use.
 After installation an adequate protection of the tense pieces must be guaranteed
 The necessary connection details can be found on the label near the connection box.
 The connection to the main plug must be made using a grounded plug or via an omnipo-
lar circuit with a fuse block with an opening of at least 3 mm.
 The electrical circuit must be separated from the network through appropriate devices,
such as fuses, or circuit breakers.
 If the appliance is not fitted with an accessible plug, a disconnection apparatus must be
used during installation
 The power cable must be positioned so that it does not come in contact with any of the
hot parts of the hob or oven.
Caution!
This appliance has only to be connected to a network 230 V~ 50/60 Hz.
Connect always the earth wire.
Respect the connection diagram.
The connection box is located underneath at the back of the hob casing. To open the cover use
a medium screwdriver. Place it in the slits and open the cover.
Mains
230V~ 50/60Hz
400V~ 50/60Hz
* calculated with the simultaneous factor following the standard EN 60 335-2-6/1990
Important
It is strictly forbidden to lengthen or shorten the wires of the cooking zones ( 5,6,7,8;)
Only the wire of the control panel (C) may be extended (Using our prolonged wire ref.
A10506/0).
Connection of the hob
Setting up the configurations:
For the various connections, use the brass jumpers which are in the box near the terminal
Monophase 230V~1P+N
st
Insert the 1
jumper between terminals 1 and 2 and the 2
Attach the ground plug to the terminal "earth", the neutral N to terminal 3 or 4, and L to either
terminal 1 or 2.
Biphase 400V~2P+N
Insert the jumper between terminals 3 and 4.
Attach the ground plug to the terminal "earth", the neutral N to terminal 3 or 4, the Phase L1 to
the terminal 1 and the Phase L2 to the terminal 2.
Caution! Make sure to have carefully secured the cables and jumpers and tightened the
screws
We cannot be held responsible for any incident resulting from the incorrect connection of
the apparatus, including the use of an apparatus that has not been grounded properly or
Connection
Cable diameter
1 Phase + N
3 x 2,5 mm²
2 Phases + N
4 x 1.5 mm²
one that has a defected grounding system.
Cable
H 05 VV - F
H 05 RR - F
H 05 VV - F
H 05 RR - F
nd
between 3 and 4.
15
Protection calibre
25 A *
16 A *