Installation Instructions
1. Mount Rough-In Enclosure using one of the following
methods (mounting hardware is not provided):
a. Surface Mount - Use keyholes shown in Figure 1 with
bolts sufficient for 100 lbs. (45 kg) load (1/4" (M6) bolts
recommended).
b. Recess Mount - Use screws sufficient for 100 lbs. (45
kg) through the corners of the enclosure (see Figure
1). Mount enclosure flush to or not more than 1/8"
(3mm) below the finished wall surface (Enclosure is 3-
7/8" (9.8cm) deep past cover mounting tabs. Enclosure
cover dimensions are 32-1/2" x 15-7/8" (83cm x
40cm)).
Caution - Power supply will hum slightly and inter-
nal relays will click while in use. Mount in a loca-
tion where such noise is acceptable.
Caution - All wiring must be installed in accor-
dance with national and local electrical codes.
Caution - This equipment is air-cooled. Mount in a
location where the vented cover will not be
blocked. 12 inches of clearance in front of the
vents is required.
Danger - Locate and lock supply breaker in the
OFF position before wiring to terminal blocks or
plugging in power cord.
Caution - This equipment is intended for indoor
use only.
2. Run 120V power wiring into the enclosure. Locations
to run power wiring into the enclosure are shown in
Figure 1. Terminal blocks will accept one 18 through 10
AWG (1-2.5mm 2 ) wire or two 18 or 16 AWG (1-1.5mm 2 )
wires (see Figure 2). Tighten terminal blocks to 3.5 to 5
in-lbs. (.40 to .57 Nm). Do not overtighten.
For increased system reliability, HomeWorks Interactive
processors can be powered by an uninterruptible power
supply (UPS) that incorporates surge protection, brown-
out protection, and battery backup. When selecting a
UPS, allow 240VA of capacity for each processor on the
UPS. A single large UPS for all processors is better than
an individual UPS for each processor. This prevents
inconsistent system operation on battery backup if the
individual UPS units power down at different times.
3. If the processor and the accessory boards have not
been installed, leave this instruction sheet in the
enclosure.
4. Install HomeWorks Interactive Processor. Install
processor in location shown in Figure 3 using the screws
installed in the enclosure. Torque mounting screws to 20
in. lbs. (2.26 Nm) max. Connect power cord from the
processor assembly to the plug coming from the terminal
blocks (see Figure 3).
HWI-ENC-LV32
HomeWorks Interactive
Low Voltage Rough-In Enclosure
Figure 1 - Enclosure Dimensions
14-3/8"
(36.5cm)
Power
Wiring
Entry
32"
(81cm)
Control
Wiring
Entry
Screws for
recess mounting
15-1/8"
(4 places)
(38.54cm)
Figure 2 - Dedicated Processor Assembly Feed
Input 120V Hot from
H
Distribution Panel
(Draw will be 2A maximum)
H
N
Input Neutral from
Distribution Panel
N
N
Ground Connection
G
Torque Terminal Blocks from 3.5 to 5 in-lbs. (0.4 to 0.57 Nm.)
Figure 3 - Dimmer Interface Board Configuration
1 2 3 4
1 2 3 4
1 2 3 4 5 6 7 8
J3
G1
V1
G2
V2
G3
V3
G4
V4
HWI-WLB
Wire Landing Board
(Class 2)
This product may be covered under one or more of the following U.S. patents:
4,797,599; 4,889,999; 5,170,068; 5,237,207 and corresponding foreign patents. U.S.
and foreign patents pending. Lutron and HomeWorks are registered trademarks of
Lutron Electronics Co., Inc.
© 1999 Lutron Electronics Co., Inc.
7"
(18cm)
H
H
N
N
N
G
.312 dia.
(8mm)
.624 dia.
(16mm)
Keyholes for
surface mounting
(4 places)
29"
UP
(74cm)
+7°
-7°
Mount Panel
Vertically
7-1/2"
(19cm)
Black
Feed Plug
White
MOVs
(Do Not Remove)
Green/Yellow
H
H
N
N
N
G
Processor
Assembly
Power Cord
HWI Processor
8
8
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4 5 6 7 8
J4
1 2 3 4
5 6 7 8
J5
G5
V5
G6
VG
G7
V7
G8
V8
G9
V9
G10 V10 G11 V11 G12 V12
1 2 3 4
HWI-D48 Dimmer
Interface Board
(Class 2)
(Do not connect
ground wire)

Publicidad

loading

Resumen de contenidos para Lutron Homeworks Interactive HWI-ENC-LV32

  • Página 1 This product may be covered under one or more of the following U.S. patents: 4,797,599; 4,889,999; 5,170,068; 5,237,207 and corresponding foreign patents. U.S. and foreign patents pending. Lutron and HomeWorks are registered trademarks of Lutron Electronics Co., Inc. © 1999 Lutron Electronics Co., Inc.
  • Página 2 Technical and Sales Assistance Warranty Lutron will, at its option, repair or replace any unit that is defective in materials or manufac- If you need assistance, call the toll-free Lutron ture within two years after the purchase. This warranty is in lieu of all other warranties, Technical Assistance Hotline.
  • Página 3 Este producto está cubierto por una o varias de las siguientes patentes: 4,797,599; 4,889,999; 5,170,068; 5,237,207, y por patentes relacionadas en países extranjeros. Patentes pendientes en EE.UU. y países extranjeros. Lutron y HomeWorks son mar- cas registradas de Lutron Electronics Co., Inc.
  • Página 4 Asistencia técnica Garantía Lutron reparará o reemplazará, a su criterio, cualquier unidad cuyos materiales o fabri- En caso de dudas sobre la instalación u operación de cación resulten defectuosos en el término de dos años después de la compra. Esta garan- este producto, llame a la Línea Directa de Asistencia...