INSTRUCTIONS MANUAL AND MAINTENANCE
SERIE ST
14. SINGLE PHASE MOTOR
Single-phase 220V motors must work with a capacitor with an adequate capacity for the power
permanently connected to the circuit.
As indicated in the image, the yellow wire is the common one and has to be connected to the L
line, interposing a suitable overload relay.
The blue wire is the phase and has to be connected to line N.
The brown wire must be connected to a connector on the capacitor; the other connector of the
capacitor must be connected to the N line together with the blue cable.
If at any time in the future you should need to dispose of this product or
any part of this product, please note that waste electrical products, bat-
teries or cables should not be disposed of with household waste. Please
teries or cables should not be disposed of with household waste. Please
recycle where facilities exist, please check with your local authority for
recycling advice.
The abandonment or uncontrolled disposal of waste can cause harm
to environment and human health. So, by recycling this product in a res-
to environment and human health. So, by recycling this product in a res-
ponsible manner, you contribute to the preservation of natural resources
and to the protection of human health.
www.proindecsa.com / proindecsa@proindecsa.com