Monitor; Front Panel; Back Panel; Right Panel - Sophysa PRESSIO 2 PSO-4000 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 65

5.1. MONITOR

5.1.1. Front Panel

[8] Battery indicator light (orange) [9] Power button
[10] Power indicator light (green) [11] Touch screen
Battery Indicator Light (orange)
When the battery indicator light glows orange, the power ca-
ble is disconnected, and the Monitor is operating on battery
power.
The battery indicator light flashes when the battery is being
charged, or when it is low. To recharge the battery, connect
the Monitor to the mains power.
Power button
When the Monitor is off, briefly pressing this button (1 sec-
ond) powers up the Monitor.
When the Monitor is already on, briefly pressing this button
(1 second) places the monitor in standby mode.
When the Monitor is operating on battery power, it is not
possible to put it on standby, and pressing this button pow-
ers off the Monitor completely.
A long continuous press of this button while powering on ac-
cesses menus reserved for maintenance of the machine.
A long continuous press of this button while the Monitor is
on will power off the Monitor.
Power Indicator Light (green)
When the power indicator light glows green, the Monitor is
operating on mains power.
Touch screen
The back-lit color touch screen displays the ICP and ICT
measurements and contains touch keys for configuring the
Monitor. Details of these keys are in section Section 5.4.
Screens (p. 14).

5.1.2. Back Panel

[12] Pole clamp [13] Air vents and loudspeaker [14] Power
Pole clamp
The pole clamp enables the Monitor to be affixed to a verti-
cal pole or a horizontal rail, with a diameter between 10 and
60 mm.
It can be swiveled 360 degrees, in 90-degree increments. To
reorient the pole clamp, rotate it in the desired direction until
it clicks into position.
WARNING
Do not dismantle the pole clamp as this could impair
the electrical safety of the Monitor.
Power inlet
The Monitor should be connected to 100-240 V, 50-60 Hz
single phase alternating current mains power with ground,
using the power cable provided.
WARNING
Correct grounding can only be ensured if the Monitor is
connected to a properly grounded outlet.

5.1.3. Right Panel

[15] Catheter extension cable inlet [16] USB 2.0 port
[17] Mini-USB port [18] ICP outlet [19] ICT outlet
inlet
Page 13 of 174

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido