<2.3> Damaged cooling fan and product overheat warning:
NOTE: After the cooling fan is removed, the FAN FAIL system and alarm will not transmit any signals.
A. When the cooling fan stops running or fails, the fan fail light will display a red light and then the alarm will start to sound. You must
press the RESET button to stop the alarm, but the red light will still be on until the fan is removed or replaced.
B. Temperature Alarm Feature:
The temperature trigger can be set at the following temperatures: 45 , 55 , 65 . (See Section 3.)
C. When the product temperature exceeds the set temperature, the OVER HEAT LED will display red and the alarm will sound.
If this issue occurs please press the RESET button to stop the alarm, but the OVER HEAT LED will remain on until the
temperature is below the set temperature.
Back Plane Description (Labeled on the top side of the Product)
3.
2
POWER PORT
HDD1
45
HDD FAIL IN
55
65
HDD2
TEMP SET
HDD3
SATA CONNECTOR
HDD1 FAIL IN
HDD2 FAIL IN
HDD3 FAIL IN
POWER1
POWER2
POWER3
ACCESS1
ACCESS2
ACCESS3
TEMP FAIL
FAN FAIL
RESET
S-OUT