Emptying The Tank - Alemite 8580 Guía De Servicio

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

SER 8580

Emptying the Tank

1. Remove Plug (23) and position the opened nozzle on
Drain Hose (22) into an appropriate collection
container.
2. Close Valves (A), (B), (C), (E), and (G).Turn Valve
(A) fully clockwise.
3. Open Ball Valves (D) and (F).
CAUTION
Do not exceed 7 psi (0.5 bar) air pressure when
emptying the extractor. Damage to components
can occur.
WARNING
If valves (A), (B), (C), (E), and (G) are not
closed, oils will shoot out of the extractor
and spray the user.
4. Set the air supply to a maximum of 7 psi (0.5 bar).
5. Attach air supply to Connector (F1), then disconnect
once the Tank is empty.
• Always disconnect the air supply immediately if
pressure relief valve (20) opens.
6. Open Ball Valve (D).
Revision (1-14)
Changes Since Last Printing
Initial Release
6
Portable Oil Drain/ Extractor
Alemite, LLC

Publicidad

Tabla de contenido
loading

Productos relacionados para Alemite 8580

Tabla de contenido