SER 8580
Emptying the Tank
1. Remove Plug (23) and position the opened nozzle on
Drain Hose (22) into an appropriate collection
container.
2. Close Valves (A), (B), (C), (E), and (G).Turn Valve
(A) fully clockwise.
3. Open Ball Valves (D) and (F).
CAUTION
Do not exceed 7 psi (0.5 bar) air pressure when
emptying the extractor. Damage to components
can occur.
WARNING
If valves (A), (B), (C), (E), and (G) are not
closed, oils will shoot out of the extractor
and spray the user.
4. Set the air supply to a maximum of 7 psi (0.5 bar).
5. Attach air supply to Connector (F1), then disconnect
once the Tank is empty.
• Always disconnect the air supply immediately if
pressure relief valve (20) opens.
6. Open Ball Valve (D).
Revision (1-14)