Specifications
Input Power Requirements
AC Input Voltage:
AC Frequency:
AC Input Current:
Power over LAN output Specification
Pin Assignments and Pola-
rity:
Output Voltage:
Output Current:
Tolerance:
Mechanical Requirement
Dimensions:
Weight:
Indicators
System Indicator:
Connectors Shielded Rj-45

Environmental Conditions

Operating Temperature:
Operating Humidity:
Storage Temperature:
Storage Humidity:
Operating Altitude:
RJ45 out Pin Define & Connection
100 – 240Vac
50 – 60 HZ
2A at 100Vac, 1A at 240Vac
(+) 4/5 (-) 7/8
Aggregate Power: 50W (48Vdc +/- 2V)
0 – 1A
±5% (Combination Of Line, Load Regulation And Initial Set)
(H) 1.5 in × (W) 4.09 in × (D) 5.43 in
(H) 3.8 cm × (W) 10.4cm × (D) 13.8 cm
13.42 lbs. (6.1Kg)
AC Power (Green)
Power Active (Red) 0.05 A<Io<1 A
Over Current Protection (Red, Flash)
32° to 104° F (0° to 40° C)
Maximum 90% Non-condensing
-13° to 185° F (-25° to 85° C)
Maximum 95%, Non-condensing
-1000 to 10,000 ft. (-304.8 to 3048 m)
INJECTOR: RJ-45 Output (Data & Power)
Pin
Symbol
1
RX+
2
RX-
3
TX+
4
Vo+
5
Vo+
6
TX-
7
Vo-
8
Vo-
Description
Data Receive
Data Receive
Data Transmit
Feeding power(+)
Feeding power(+)
Data Transmit
Feeding power(-)
Feeding power(-)