STEP 3
Assemble the System and Install Optional Mounting Bracket
1
Dry assemble the complete system (according to the configuration chosen), including all fittings and valves.
2
When installing the optional mounting bracket (not included), position it on top of the System Head
with the holes in the System Head. Insert four mounting screws (not included), through the mounting bracket and into the holes of the
System Head until tight.
3
Measure the overall length (see diagram) of the configured system.
4
Reduce this measurement enough to allow for the amount of engagement (X) to determine how much pipe to remove from the line.
STEP 4
Mark Measurements and Cut the Plumbing Pipe
CAUTION
1
Mark the section of the plumbing pipe that will need to be removed (X) to allow for the configured system (as determined in Step 3).
NOTE: Measure twice, cut once!
2
Using a pipe cutter or hacksaw, cut the marked section from the plumbing pipe.
NOTE: Use a pan or bucket to catch any remaining water in the pipes.
3
Remove any burrs or debris from the cut edges with a file.
WFHD13001
Please wear safety glasses to protect eyes when cutting.
A,
aligning the bracket holes
5
3
MOUNTING
SCREWS
(NOT INCLUDED)
2
MOUNTING
BRACKET
(NOT INCLUDED)
A
3
4
X
A
SEE CHART
PAGE 3
4
V4.1E