Verificare il corretto funzionamento di tutti i dispositivi di sicurezza installati al fine di ridurre al minimo ogni eventuale rischio.
•
Istruire il personale addetto all'uso dell'automazione sui relativi comandi, dispositivi di sicurezza e pericolosità derivante dall'uso
dell'automazione.
•
Compilare il fascicolo tecnico ed adempiere agli eventuali obblighi derivanti dalle normative vigenti.
GB
1.
Safety rules
Warning: Any repairing, fitting or adjustment made from people not qualified are strictly forbidden and in order to avoid any possible
accident, all necessary precautions must been taken (ex: switch off the power supply as well as disconnect batteries).
Warning: Daspi is not responsible for possible damages or injuries to people, objects or animals caused by any unauthorized
modification of product.
Warning: Do not install this product into an explosive place
Keep scrupulously this booklet and include it into the main user manual in a suitable place well known by all the interested
people.
2.
Model
The control panel MACH1E has been designed for driving 1 operator for sliding gates mod. MAX and it has an electric clutch. Daspi is
not responsible for any different use of control panel MACH1E
3.
List of main components
TR1
Transformer: main tension 230 Vac – secondary
tension 24 Vac
F1
Net protection's fuse 5A
F2
Controls protection's fuse 2A
SW1
Dip-switches for control panel programming
J1
Receiver terminal
Leds showing control panel entrances connections (switching on after power supply has been connected)
DL1
Switching on by START shows that operator is working properly. When flashing it means anomaly on the operator or anti-
crashing system UDS active.
DL2
Always switched on, it switches off by STOP
DL3
Always switched off, it switches on by START
DL4
Always switched on, it switches off by control
safety device "COSTA"
Check again the connections and the devices if the above led don't correspond .
4.
Control panel programming and adjusting
The programming of dip switches must be made with control panel switched off
SW1
It cancels control START during opening (residential system)
1
It sets automatic shutting of gates with time adjustable by
2
trimmer R2
Photocells working in opening. With an obstacle the gate stops;
3
it starts again opening after the obstacle has been removed.
4
It sets a flashing of 2 sec. before any movement.
Adjusting of trimmers: R1 electric clutch – R2 Break – R3 Working time
R1 – POWER
Maximum and minimum pushing power of motor. It must
be checked periodically and adjusted following to the
actual norms..
5.
Terminals descriptions
Join with a bridge the N.C. (normally closed) entrances you don't used
If you are using more contacts N.C. on same entrance, they must be connected in set.
If you are using more contacts N.O. on same entrance, they must be connected in parallel
1
Entrances 1 and 2 for power supply 230
2
Vac 50 Hz
3
Terminal 3 earth connection
4
Entrances for flashing light 220 Vac max.
5
25 Watt
6
Motor exit.
7
6 Common – 7 Open – 8 Close
8
Capacitor to terminals 7-8
9
Entrance for limit switches close
10
Contact N.C.
9
Entrance for limit switches open
11
Contact N.C.
14
Entrance for photocells. During closing they stop the gate and re-start opening.
12
Contact N.C.
J2
JP1
JP2
JP3
DL5
DL6
DL7
ON
It counts the time of
break after opening and
before closing.
14
13
14
15
14
16
17
18
19
20
Terminal for anti-crashing system UDS. It allows the gate to invert
the stroke of 10 cm when an obstacle stops its movement.
Terminals for power supply connection 230 Vac 50 Hz
Terminals for operator and flashing light connection
Terminals for electronic and safety devices connection
Always switched on, it switches off by control PHOTOCELLS
Always switched on, it switches off by control LIMIT SWITCHES
OPEN
Always switched on, it switches off by control LIMIT SWITCHES
CLOSE
Control START always active. if set during opening it stops
the operator
Automatic shutting not working.
Photocells working only in closing. With an obstacle the gate
stops and re-open
Flashing before any movement deactivated
R2 – BREAK
It counts the working time either in opening and
closing. Time must be always adjusted 2-3
seconds more than real movement time of gate
Entrance for safety face device. During opening it stops the
movement and re-start closing for 10 cm.
Contact N.C.
Entrance START. If set during opening it stops the movement; if set
during closing invert the movement. Contact N.O.
Entrance STOP. If set it stops any movement and cancel the
automatic shutting.
Contact N.C.
Exit 24 Vac for external devices as well as extra photocells
Entrance for antenna: 19 hot pole – 20 copper cable
OFF
R3 – WORK