Service
During cleaning and service of the unit, the unit
should be disconnected from the power supply.
The fi ne fi lter should be changed at least once per
year. Use only original parts for replacement. If
the unit is equipped with a HEPA fi lter, this fi lter
should be changed every 300 working hours. Use
breathing protection and perform this operation in
a contained area. The used fi lter should be placed
in containment and disposed of in the proper and
prescribed method.
Filter change:
Remove the motor head. Lift the fi lter straight up out
of the cyclone. When required, a plastic sack can be
placed over the cyclone for dust-free fi lter change.
The fi lter is lifted directly into the sack.
During the fi lter change, check the fi lter gasket. A
damaged gasket can allow the release of hazardous
dust. Never use old gaskets or after-market fi lters. Use
only genuine Dustcontrol spare parts to maintain the
unit for use on hazardous dusts.
Check regularly that the electrical cable is not dama-
ged. The DC 1800 should be performance tested at
least once per year because it may be used with ha-
zardous materials. Worn parts must be replaced.
The vacuum motor is maintenance free.
Filterchange HEPA fi lter: Start with to turn the mo-
tor unit up put a plastic sac over the HEPA fi lter, loose
the fi lter and seal the used fi lter in the plastic sac.
Then you mount a new fi lter according to below:
1.
2.
Part No. 42027
4.
5.
7.
DC 1800
3.
6.
11
Part No 94114